Show simple item record

dc.contributor.advisorSuyatma, Nugraha Edhi
dc.contributor.advisorSupriyadi, Slamet
dc.contributor.authorSHABRINA, BELVA SYARAFINA NUR
dc.date.accessioned2026-08-04T00:07:07Z
dc.date.available2026-08-04T00:07:07Z
dc.date.issued2026
dc.identifier.urihttp://repository.ipb.ac.id/handle/123456789/176948
dc.description.abstractKebutuhan produk susu lactose free meningkat seiring tingginya prevalensi intoleransi laktosa. Akan tetapi, proses hidrolisis laktosa di industri masih memerlukan waktu yang relatif panjang sehingga menyebabkan efisiensi produksi menjadi terbatas. Penelitian ini bertujuan mengkaji pengaruh variasi suhu dan waktu terhadap efektivitas hidrolisis laktosa serta menentukan kondisi proses yang paling efisien tanpa menurunkan mutu produk. Penelitian ini menggunakan pendekatan eksperimental eksploratif melalui variasi suhu 9°C, 13°C, 40°C, dan 45°C dengan kombinasi waktu inkubasi serta evaluasi bertahap menggunakan uji sensori, analisis kadar laktosa, pH, uji alkohol, dan Total Plate Count (TPC). Hasil menunjukkan bahwa kondisi 13°C selama 12 jam dan 40°C selama 2 jam mencapai kadar laktosa <0,008% sehingga memenuhi kriteria bebas laktosa. Kedua kondisi menghasilkan mutu sensori, nilai pH, stabilitas protein, dan keamanan mikrobiologis yang setara dengan proses existing (8°C selama 18 jam) dengan waktu yang lebih singkat. Modifikasi kondisi proses mampu mengurangi waktu proses sebesar 33% pada kondisi 13°C selama 12 jam dan 88% pada kondisi 40°C selama 2 jam tanpa menyebabkan perubahan signifikan terhadap karakteristik produk. Kondisi 40°C selama 2 jam ditetapkan sebagai kondisi terbaik karena memberikan efisiensi tertinggi, sedangkan kondisi 13°C selama 12 jam direkomendasikan sebagai alternatif berbasis cold hydrolysis yang lebih mudah diintegrasikan dengan sistem pendinginan industri.
dc.description.abstractThe demand for lactose-free milk continues to increase due to the high prevalence of lactose intolerance. However, lactose hydrolysis in the dairy industry requires a relatively long processing time, limiting production efficiency. This study aimed to evaluate the effect of process temperature and incubation time on lactose hydrolysis effectiveness and determine the most efficient processing condition without compromising product quality. An exploratory experimental approach was applied using temperatures of 9°C, 13°C, 40°C, and 45°C with different incubation times, followed by sensory analysis, lactose analysis, pH measurement, alcohol test, and Total Plate Count (TPC). The results showed that hydrolysis at 13°C for 12 hours and 40°C for 2 hours achieved lactose levels below 0.008%, meeting lactose-free criteria. Both conditions produced sensory quality, pH, protein stability, and microbiological quality comparable to the existing process (8°C for 18 hours) with shorter processing time. The modified conditions reduced processing time by 33% at 13°C for 12 hours and by 88% at 40°C for 2 hours without significantly affecting product characteristics. The 40°C for 2 hours condition was identified as the best processing condition, whereas 13°C for 12 hours is recommended as an alternative cold hydrolysis process readily integrated into existing industrial cooling systems.
dc.description.sponsorship
dc.language.isoid
dc.publisherIPB Universityid
dc.titlePengaruh Modifikasi Suhu dan Waktu Proses terhadap Efektivitas Hidrolisis Laktosa pada Produksi Susu Lactose Free di PT XYZid
dc.title.alternativeEffect of Process Temperature and Time Modification on the Effectiveness of Lactose Hydrolysis in the Production of Lactose-Free Milk at PT XYZ
dc.typeSkripsi
dc.subject.keywordenzim laktaseid
dc.subject.keywordhidrolisis laktosaid
dc.subject.keywordsuhuid
dc.subject.keywordsusu lactose freeid
dc.subject.keywordWaktuid
dc.subject.keywordlactase enzymeid
dc.subject.keywordlactose hydrolysisid
dc.subject.keywordlactose-free milkid
dc.subject.keywordtemperatureid
dc.subject.keywordtimeid
dc.subtypeUndergraduate Theses


Files in this item

Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record