Show simple item record

dc.contributor.advisorHapsari, Rianti Dyah
dc.contributor.advisorSuhaima, Nurafi Razna
dc.contributor.authorFauziyah, Novianty
dc.date.accessioned2026-08-04T08:41:35Z
dc.date.available2026-08-04T08:41:35Z
dc.date.issued2026
dc.identifier.urihttp://repository.ipb.ac.id/handle/123456789/177021
dc.description.abstractPenelitian ini bertujuan mengevaluasi kecukupan proses panas pada minuman susu cair ready to drink (RTD) dalam botol kaca di PT XYZ untuk memastikan keamanan mikrobiologis dan mutu produk. Evaluasi meliputi kinerja autoklaf, distribusi dan penetrasi panas (F0), serta analisis sensori dan fisikokimia sebelum dan sesudah pemanasan. Hasil menunjukkan adanya gap suhu ±2 °C dan lag time ±9 menit. Distribusi panas merata dan stabil, dengan titik 1 sebagai cold spot, sementara tabung silinder tidak direkomendasikan. Nilai F0 sebesar 8,63 menit (trapesium) dan 5,73 menit (Ball) telah memenuhi standar steril komersial BPOM (=3 menit). Sterilisasi tidak berpengaruh signifikan terhadap sensori, pH dan aktivitas air tetap stabil, namun viskositas meningkat. Secara keseluruhan, proses dinilai aman dan layak, dengan rekomendasi optimasi holding time dan uji umur simpan lanjutan.
dc.description.abstractThis study aims to evaluate the adequacy of the thermal process applied to ready to drink (RTD) liquid milk packaged in glass bottles at PT XYZ to ensure microbiological safety and product quality. The evaluation includes autoclave performance, heat distribution and penetration (F0), as well as sensory and physicochemical analyses before and after heat treatment. The results show a temperature deviation of ±2 °C and a lag time of ±9 minutes. Heat distribution was uniform and stable, with point 1 identified as the cold spot, while the use of cylindrical containers was not recommended. The F0 values of 8.63 minutes (trapezoidal method) and 5.73 minutes (Ball method) met the BPOM commercial sterility standard (=3 minutes). Sterilization did not significantly affect sensory attributes, while pH and water activity remained stable, although viscosity increased. Overall, the process is considered safe and feasible, with recommendations for holding time optimization and further shelf-life studies.
dc.description.sponsorship
dc.language.isoid
dc.publisherIPB Universityid
dc.titleEvaluasi Kecukupan Proses Panas pada Produk Ready To Drink (RTD) dalam Kemasan Botol Kaca di PT XYZid
dc.title.alternativeEvaluation of the Adequacy of Heat Processes in Ready to Drink (RTD) Products in Glass Bottles at PT XYZ
dc.typeTugas Akhir
dc.subject.keywordkecukupan proses panasid
dc.subject.keywordready to drink (RTD)id
dc.subject.keywordnilai letalitas (F0)id
dc.subject.keywordsterilisasi komersialid
dc.subject.keywordcommercial sterilizationid
dc.subject.keywordlethality value (F0)id
dc.subject.keywordready to drink (RTD) beverageid
dc.subject.keywordthermal process adequacyid
dc.subtypeUndergraduate Theses


Files in this item

Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record