Inaktivasi Biofilm Bacillus cereus dengan Sanitaiser Komersial Berbasiskan Asam Perasetat
Abstract
Bacillus cereus menjadi perhatian bagi industri pangan karena berpotensi
membentuk biofilm pada permukaan stainless steel (SS). Spora B. cereus yang
bertahan selama pengolahan pangan dapat bergerminasi jika terpapar kondisi
menguntungkan, maka dapat membentuk biofilm yang umumnya memilki
resistensi terhadap panas maupun senyawa sanitaiser. Beberapa senyawa sanitaiser
yang efektif menginaktivasi biofilm telah banyak dijabarkan pada literatur, salah
satunya adalah asam perasetat. Asam perasetat terbuat dari campuran hidrogen
peroksida dan asam asetat. Asam perasetat termasuk ke dalam golongan oksidan
kuat. Mekanisme asam perasetat dalam menginaktivasi bakteri diduga dengan
mendenaturasi protein dan mengganggu permeabilitas dinding sel. Asam perasetat
banyak digunakan pada permukaan peralatan maupun pangan segar karena tidak
memiliki dampak toksikologi. Penggunaan asam perasetat dalam proses sanitasi
meningkat karena termasuk ke dalam senyawa yang tergolong aman, sebab hasil
dekomposisinya berupa asam asetat dan air yang tidak menimbulkan dampak buruk
pada lingkungan.
Penelitian ini bertujuan untuk mengevaluasi kemampuan sanitaiser
komersial berbasis asam perasetat dalam menginaktivasi biofilm Bacillus cereus,
menentukan konsentrasi dan waktu kontak optimal untuk menghasilkan penurunan
biofilm terbesar, serta mengamati perubahan struktur biofilm oleh perlakuan
sanitaiser berbasiskan asam perasetat. Sanitaiser komersial yang digunakan
meliputi MT Peroxy 404 HC® (A; asam perasetat), MT Oxyquart 405® (B; asam
perasetat dan quat), Bioclean 510® (C; asam perasetat, quat, air alkali dan hidrogen
peroksida), MT Oxyquart 408® (D; asam perasetat, quat, dan air alkali), Bioclean
500® (E; asam perasetat, air alkali, dan hidrogen peroksida), acidified peroxyacetic
acid (F; asam perasetat dan air asam), dan alkalized peroxyacetic acid (G; asam
perasetat, air alkali, dan NaCl). Penelitian ini terbagi menjadi 3 tahap. Tahap
pertama adalah untuk memperoleh informasi mengenai sanitaiser komersial
berbasiskan asam perasetat yang mampu membunuh B. cereus pada konsentrasi
yang direkomendasikan oleh produsen. Tahap kedua adalah mengevaluasi
efektivitas sanitaiser komersial terpilih terhadap biofilm B. cereus. Tahap ketiga
adalah untuk mengamati morfologi bofilm B. cereus setelah perlakuan sanitaiser.
Hasil penelitian menunjukkan bahwa semua sanitaiser yang diuji mampu
menghambat B. cereus. Pemaparan biofilm B. cereus pada pelat SS dengan
sanitaiser komersial B yang mengandung asam perasetat dan quat atau F yang
mengandung asam perasetat dan air asam efektif menurunkan densitas biofilm B.
cereus. Sanitaiser B yang dipaparkan selama 5 menit pada konsentrasi 200 ppm
menghasilkan reduksi tertinggi terhadap biofilm B. cereus dan menyebabkan
kerusakan morfologi yang diduga menginaktivasi bakteri biofilm B. cereus. Bacillus cereus becomes the concern for the food industry because it has the
potential to form biofilms on stainless steel (SS) surfaces. Spores of B. cereus that
survive during food processing can germinate if exposed to favorable conditions,
and can form biofilms which generally resistance to heat and sanitary
compounds.Several sanitizing compounds that are effective in inactivating biofilms
have been described in the literature, one of which is peracetic acid. Peracetic acid
is made from a mixture of hydrogen peroxide and acetic acid. Peracetic acid belongs
to the group of strong oxidants. The mechanism of peracetic acid in inactivating
bacteria is thought to be by denaturing proteins and disrupting cell wall
permeability. Peracetic acid is widely used on the surface of equipment and fresh
food, because it has no toxicological impact. The use of peracetic acid in the
sanitation process is increasing because it is included in a compound that is
classified as safe, because the decomposition products are acetic acid and water
which do not have a negative impact on the environment.
This study aimed to evaluate the ability of peracetic acid-based commercial
sanitizer in inactivating Bacillus cereus biofilm, determine the optimal
concentration and contact time to obtain the greatest biofilm reduction, and observe
changes in the biofilm structure by the treatment of peracetic acid-based sanitizer.
Commercial sanitizers used include MT Peroxy 404 HC® (A; peracetic acid), MT
Oxyquart 405® (B; peracetic and quatic acid), Bioclean 510® (C; peracetic acid,
quat, alkaline water and hydrogen peroxide), MT Oxyquart 408® (D; peracetic
acid, quat, and alkaline water), Bioclean 500® (E; peracetic acid, alkaline water,
and hydrogen peroxide), acidified peroxyacetic acid (F; peracetic acid and acidic
water), and alkalized peroxyacetic acid ( G; peracetic acid, alkaline water, and
NaCl). This research is divided into 3 stages. The first stage was to obtain
information on commercial peracetic acid based sanitizers capable of killing B.
cereus at concentrations recommended by the manufacturer. The second stage was
to evaluate the effectiveness of the selected commercial sanitaiser against B. cereus
biofilm. The third stage was to observe the morphology of B. cereus with scanning
electron microscopy after sanitizing treatment.
The results showed that all tested sanitizers were able to inhibit B. cereus.
Exposure of B. cereus biofilms on SS plate with sanitizer B containing peracetic
acid and quat or F containing peracetic acid and acidic water was effective in
reducing the density of B. cereus biofilms. Sanitizer B exposed for 5 minutes at
200 ppm resulted in the highest reduction of B. cereus biofilms and caused
morphological damage which was thought to inactivate B. cereus bacteria biofilms.
Collections