IPB University Logo

SCIENTIFIC REPOSITORY

IPB University Scientific Repository collects, disseminates, and provides persistent and reliable access to the research and scholarship of faculty, staff, and students at IPB University

AI Repository
 
Building and Categories


      View Item 
      •   IPB Repository
      • Final Assignments
      • Undergraduate Final Assignments
      • UF - Vocational School
      • UF - Chemistry Analysis
      • View Item
      •   IPB Repository
      • Final Assignments
      • Undergraduate Final Assignments
      • UF - Vocational School
      • UF - Chemistry Analysis
      • View Item
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      Optimasi dan Validasi Metode Penentuan Fluorida dalam Air Sungai secara Spektrofotometri Sinar Tampak

      Thumbnail
      View/Open
      Cover (372.9Kb)
      Fulltext (934.8Kb)
      Lampiran (407.1Kb)
      Date
      2026
      Author
      Saputra, Sebin Doni
      Andrianto, Dimas
      Rosadi
      Metadata
      Show full item record
      Abstract
      Air sungai merupakan sumber air baku yang memerlukan pemantauan kualitas, salah satunya melalui analisis ion fluorida. Penelitian ini bertujuan mengembangkan dan memvalidasi metode spektrofotometri sinar tampak berbasis kompleks asam zirkonil-SPADNS untuk penentuan fluorida dalam air sungai. Uji kestabilan serapan menunjukkan bahwa kompleks stabil pada rentang waktu 10–15 menit setelah penambahan reagen. Optimasi kondisi analisis dilakukan menggunakan Response Surface Methodology dengan desain Box-Behnken dan menghasilkan kondisi optimum pada pH 3,0, konsentrasi zirkonil 0,009%, dan waktu reaksi 10 menit. Metode yang dikembangkan memenuhi seluruh kriteria validasi, meliputi linearitas, presisi, akurasi, limit kuantifikasi, limit deteksi metode, dan ketidakpastian pengukuran. Secara keseluruhan, penelititan mengenai optimasi dan valiadasi metode spektrofotometri sinar tampak berbasis kompleks asam zirkonil-SPADNS menunjukkan kinerja analitis yang baik dan memenuhi seluruh parameter validasi sehingga layak diterapkan untuk analisis fluorida dalam air sungai.
       
      River water is an important source of raw water that requires regular quality monitoring, including fluoride analysis. This study aimed to develop and validate a visible spectrophotometric method based on the zirconyl-SPADNS complex for the determination of fluoride in river water. The absorbance stability test showed that the complex remained stable within 10–15 minutes after reagent addition. Analytical conditions were optimized using Response Surface Methodology with a Box–Behnken design, resulting in optimum conditions of pH 3.0, 0.009% zirconyl concentration, and a 10-minute reaction time. The developed method satisfied all validation criteria, including linearity, precision, accuracy, limit of quantification, method detection limit, and measurement uncertainty. Overall, the optimized and validated method demonstrated satisfactory analytical performance and is suitable for fluoride determination in river water.
       
      URI
      http://repository.ipb.ac.id/handle/123456789/177827
      Collections
      • UF - Chemistry Analysis [135]

      Copyright © 2020 Library of IPB University
      All rights reserved
      Contact Us | Send Feedback
      Indonesia DSpace Group 
      IPB University Scientific Repository
      UIN Syarif Hidayatullah Institutional Repository
      Universitas Jember Digital Repository
        

       

      Browse

      All of IPB RepositoryCollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

      My Account

      Login

      Application

      google store

      Copyright © 2020 Library of IPB University
      All rights reserved
      Contact Us | Send Feedback
      Indonesia DSpace Group 
      IPB University Scientific Repository
      UIN Syarif Hidayatullah Institutional Repository
      Universitas Jember Digital Repository