Show simple item record

dc.contributor.advisorUlum, Mokhamad Fakhrul
dc.contributor.advisorWulansari, Retno
dc.contributor.authorSativa, Ryza
dc.date.accessioned2026-07-23T06:52:28Z
dc.date.available2026-07-23T06:52:28Z
dc.date.issued2026
dc.identifier.urihttp://repository.ipb.ac.id/handle/123456789/175592
dc.description.abstractPenggunaan implan hormon intravaginal merupakan salah satu metode sinkronisasi estrus pada ternak, namun informasi mengenai biokompatibilitas sistemiknya masih terbatas. Penelitian ini bertujuan menganalisis profil darah dan mengevaluasi dampak fisiologis pemasangan implan hormon intravaginal pada domba Garut. Sebanyak 10 ekor domba Garut betina dibagi ke dalam lima kelompok perlakuan, yaitu CIDR, plasebo, Single-hormone, Double-hormone, dan Multi-hormone. Sampel darah dikoleksi sebelum implantasi, selama implantasi, dan setelah eksplantasi, kemudian dianalisis menggunakan hematology analyzer. Data dianalisis dengan Repeated Measures ANOVA. Sebagian besar parameter hematologi berada dalam rentang fisiologis normal. Perubahan signifikan ditemukan pada MCV, MCHC, RDW, trombosit, PCT, P-LCR, dan persentase neutrofil, tanpa disertai gangguan klinis maupun indikasi respons penolakan sistemik. Implan hormon intravaginal menunjukkan biokompatibilitas yang baik dan relatif aman digunakan pada domba.
dc.description.abstractIntravaginal hormone implants are widely used for estrus synchronization in livestock, but their biocompatibility requires further evaluation. This study analyzed blood profiles and physiological responses to intravaginal hormone implantation in Garut sheep. Ten female Garut sheep were assigned to five treatment groups: CIDR, placebo, Single-hormone, Double-hormone, and Multi-hormone. Blood samples were collected before implantation, during implantation, and after explantation and analyzed using a hematology analyzer. Data were analyzed using Repeated Measures ANOVA. Most hematological parameters remained within normal physiological ranges. Significant changes were observed in MCV, MCHC, RDW, platelet count, PCT, P-LCR, and neutrophil percentage, without clinical abnormalities or evidence of systemic rejection. These findings indicate that intravaginal hormone implants have good biocompatibility and are relatively safe for use in Garut sheep.
dc.description.sponsorship
dc.language.isoid
dc.publisherIPB Universityid
dc.titleProfil Darah Domba Garut Pasca Pemasangan Implan Hormon Intravaginalid
dc.title.alternativeBlood Profile Garut Sheep After Intravaginal Hormone Implant Installation
dc.typeSkripsi
dc.subject.keywordbiokompatibilitasid
dc.subject.keywordDomba Garutid
dc.subject.keywordHematologiid
dc.subject.keywordimplan intravaginalid
dc.subject.keywordsinkronisasi estrusid
dc.subtypeUndergraduate Theses


Files in this item

Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record