dc.description.abstractKebutuhan air irigasi pada lahan pertanian yang elevasinya lebih tinggi dari pada sumber air pasti membutuhkan pompa sebagai tenaga pengalirannya, salah satu pompa yang hemat energi adalah pompa hidram yang mengubah energi jatuh air menjadi energi penggerak pompa. Bangunan pelimpas embung SDGs memiilki tinggi jatuh air yang dapat dimanfaatkan pompa hidram untuk mengaliri lahan pertanian Cikabayan, sehingga diperlukan rancangan pengaliran air dari saluran pelimpas menuju lahan pertanian cikabayan dengan memanfaatkan pompa hidram. Hasilnya didapatkan kebutuhan air irigasi adalah 1,08 lt/det dan dipilih pompa hidram dengan debit 1,04 lt/det, debit pemompaan tidak berbeda jauh dari kebutuhan air irigasi dan dapat bertambah karena rasio tinggi jatuh dan angkat yang direncanakan masih lebih kecil dari pada tabel estimasi debit pemompaan. Perhitungan nilai head loss dari statis dan dinamis dari pompa hidram menuju reservoir terdapat head loss total sebesar 15,91 m sehingga lebih kecil dari pada rencana pemompaan yaitu 25 m dan pompa hidram dapat dijalan kan sesuai kebutuhan air lahan pertanian Cikabayanid
dc.description.abstractThe need for irrigation water on agricultural land whose elevation is higher than the water source definitely requires a pump as a drainage power, one of the energy-efficient pumps is a hydraulic pump that converts the energy of falling water into pump driving energy.. The SDGs reservoir spillway building has a high water fall that can be used by hydraulic pumps to drain Cikabayan agricultural land, so a design is needed to drain water from the spillway to Cikabayan agricultural land by utilizing a hydraulic pump. The result was that the irrigation water requirement was 1.08 lt/sec and a hydraulic pump with a discharge of 1.04 lt / sec was selected, the pumping discharge did not differ much from the irrigation water requirement and could increase because the ratio of falling height and planned lifting was still smaller than the pumping discharge estimation table. The calculation of the head loss value from static and dynamic from the hydraulic pump to the reservoir has a total head loss of 15.91 m so that it is smaller than the pumping plan, which is 25 m and the hydraulic pump can be run according to the water needs of Cikabayan agricultural landid
dc.language.isoidid
dc.publisherIPB Universityid
dc.titlePerancangan Pompa Hidram Penyalur Air Embung SDGs Sebagai Penyedia Air Lahan Penelitian Cikabayanid
dc.typeUndergraduate Thesisid
dc.subject.keywordhead lossid
dc.subject.keywordirrigationid
dc.subject.keywordhydraulic pumpid