| dc.description.abstract | Logam stainless steel dalam dunia medis sudah banyak diaplikasikan sebagai
material implan tulang, tetapi logam stainless steel tanpa penyalutan oleh
biomaterial seperti hidroksiapatit (HAp) akan menimbulkan masalah karena rentan
terhadap korosi. HAp juga perlu dikompositkan dengan kitosan dan TiO2 untuk
meningkatkan kekuatan mekanik dan sifat antibakterinya agar proses implan tidak
menimbulkan masalah seperti infeksi pascaoperasi. Kajian pustaka ini bertujuan
mengevaluasi potensi logam stainless steel yang dilapisi komposit HAp-TiO2-
kitosan menggunakan metode yang tepat agar memiliki sifat antibakteri dan
ketahanan korosi yang baik sehingga dapat biokompatibel di dalam tubuh. Logam
stainless steel yang disalutkan dengan komposit berpotensi memiliki sifat
antibakteri karena terdapat TiO2 dan kitosan yang mampu menghambat bakteri.
Selain itu, penambahan TiO2 dan kitosan dapat meningkatkan ketahanan korosi
karena komposit yang tersalut akan membentuk ketebalan lapisan yang merata di
permukaan logam. Metode elektroforesis deposisi adalah metode yang tepat dalam
penyalutan ini karena menghasilkan lapisan dengan komposisi yang tepat dengan
kekuatan adhesi yang baik serta ketebalan yang bervariasi. | id |
| dc.description.abstract | Stainless steel metal in the medical world has been widely applied as a bone
implant material, but stainless steel metal without coating by biomaterials such as
hydroxyapatite (HAp) will cause problems because it is susceptible to corrosion.
HAp also needs to be composited with chitosan and TiO2 to increase its mechanical
strength and antibacterial properties so that the implant process does not cause
problems such as postoperative infection. This literature review aims to evaluate
the potential of stainless steel coated with HAp-TiO2-chitosan composite using the
suitable method to have good antibacterial and corrosion resistance properties to be
biocompatible in the body. Stainless steel metal coated with the composite has the
potential to have antibacterial properties because there is TiO2 and chitosan which
can inhibit bacteria. In addition, the addition of TiO2 and chitosan can improve
corrosion resistance because the coated composite will form an even layer thickness
on the metal surface. The deposition electrophoresis method is suitable for coating
because it produces a layer of the right composition with good adhesion strength
and varying thickness. | id |
| dc.language.iso | id | id |
| dc.publisher | IPB University | id |
| dc.title | Kajian Pustaka Penyalutan Komposit Hidroksiapatit-TiO2-Kitosan Pada Paduan Logam Stainless Steel Sebagai Material Implan Tulang | id |
| dc.type | Undergraduate Thesis | id |
| dc.subject.keyword | biocompatibility | id |
| dc.subject.keyword | chitosan | id |
| dc.subject.keyword | hydroxyapatite | id |
| dc.subject.keyword | stainless steel | id |
| dc.subject.keyword | TiO2 | id |