| dc.contributor.advisor | Erizal | |
| dc.contributor.author | Prabu, Sangga Jabbar Prawiseno | |
| dc.date.accessioned | 2021-08-07T10:10:36Z | |
| dc.date.available | 2021-08-07T10:10:36Z | |
| dc.date.issued | 2021-08-06 | |
| dc.identifier.uri | http://repository.ipb.ac.id/handle/123456789/108209 | |
| dc.description.abstract | Pertumbuhan penduduk mengakibatkan semakin sedikitnya lahan untuk membangun bangunan. Namun, ada hal yang harus diperhatikan dalam membangun gedung bertingkat yaitu penahan gaya gempa yaitu penggunaan dinding geser. Namun jenis dinding geser memiliki banyak jenis. Oleh karena itu, pada penelitian ini akan dibandingkan tipe L-Shape dan tipe Coupled SW. Pemodelan bangunan menggunakan program Etabs V9.5. mengacu pada SNI 1726:2019. Perilaku struktur yang ditinjau adalah berat total bangunan, analisis simpangan antar lantai, dan analisis P-delta. Tujuan dari penelitian ini yaitu menganalisis perbandingan perilaku struktur gedung empat lantai dengan pasangan shear wall tipe L-Shape dan tipe Coupled SW serta desain struktur yang paling efisien dalam hal kekakuan dari kedua tipe yang digunakan. Hasil yang diperoleh adalah berat total bangunan pada model shear wall berbentuk-L lebih ringan yaitu 26788 kN dibandingkan tipe coupled SW yaitu 26891 kN. Kemudian gaya geser yang diperoleh untuk tipe coupled SW memiliki gaya geser struktural yang lebih kecil dibandingkan dengan tipe L-shape. maka tipe coupled SW memiliki respon gempa yang besar dan kekakuan lebih besar daripada tipe L-shape. | id |
| dc.description.abstract | Population growth resulted in less land to build buildings. However, there
are things that must be considered in building multi-storey buildings, namely
earthquake resistance, namely the use of shear walls. However, there are many
types of shear walls. Therefore, in this study, we will compare the L-Shape type and
the Coupled SW type. Building modeling using Etabs V9.5 program. refers to SNI
1726:2019. The behavior of the structure reviewed is the total weight of the
building, the analysis of the deviation between floors, and the analysis of P-delta.
The purpose of this study is to analyze the comparison of the behavior of the fourstory building structure with L-Shape and Coupled SW type shear wall pairs and
the most efficient structural design in terms of stiffness of the two types used. The
results obtained are the total weight of the building on the L-shaped shear wall
model is lighter, which is 26788 kN compared to the coupled SW type, which is
26891 kN. Then the shear force obtained for the coupled SW type has a smaller
structural shear force compared to the L-shape type. then the coupled SW type has
a large earthquake response and greater stiffness than the L-shape type | id |
| dc.language.iso | id | id |
| dc.publisher | IPB University | id |
| dc.title | Analisis Perbandingan Perilaku Struktur Gedung 4 Lantai dengan Pasangan Shear Wall Tipe L-Shape Dan Coupled SW | id |
| dc.title.alternative | Comparative Analysis of Behavioral Structure of a 4-Story Building with Shear Wall Pairs Type L-Shape And Coupled SW | id |
| dc.type | Undergraduate Thesis | id |
| dc.subject.keyword | Etabs | id |
| dc.subject.keyword | shear wall L-shape | id |
| dc.subject.keyword | shear wall coupled SW | id |
| dc.subject.keyword | SNI 1726:2019. | id |