Please use this identifier to cite or link to this item:
http://repository.ipb.ac.id/handle/123456789/62335| Title: | Analisis Lingkungan Mikro Dengan Teknik Computational Fluid Dynamics (CFD) pada Kandang Domba Garut Sistem Tertutup di Kandang Penggemukan Fakultas Peternakan IPB |
| Authors: | Widyarti, Meiske Oktavia, Y offa |
| Keywords: | Bogor Agricultural University (IPB) Micro Climate Garut Sheep Fattening Cage CFD, |
| Issue Date: | 2010 |
| Abstract: | Cage has a very important role in accommodating all livestock activities .1\Ifh as providing comfort and protection from environmental 'hi1-l.uences. Livestock will be able to develop and grow normally in good cage environment condition. Livestock development is influenced by the climate of the ~ge microenvironment such as air temperature, humidity, wind speed, and light j tensity. ~ This research aimed to analyze the distribution of temperature, humidity, "S!ind speed and air flow patterns inside the cage with the fan turning on and off ~ith a technique of Computational Fluid Dynamics (CFD). The parameteres ~hich were observed included temperature, relative humadity (RH), air flow and iradiation with the uniform environmental conditions from 07.00 a.m. until 15:00 l-m. Then, the data obtained were analyzed and compared with simulation results esing SolidWork 2009. "tI The highest temperature inside the cage based on measurement was 33.33 ~ at 12.00 p.m., with the simulation results using SolidWork 2009 up to 34.45 t . Error of temperature based on measurement results with simulation results at gg .OO, 12.00 and 15.00 were 5.24%, 2.83%, and 2.01%. pThe highest relative itmidity based on measurements was 89.67% in the morning and evening, during &., e simulation up to 85.17% at 08.00 p.m. RH errors from the measurement results with simulations were 2.97%, 5.07%, and 3.93%. The highest wind speed from CFD simulation results was 1.90 m/sec at 15.00 p.m. The simulation results showed that the temperature level and RH when the fan was on and off were almost the same, with the difference about ± 0.01 DC, and the air movement had a difference of about 0.02-0.11 m/sec. |
| URI: | http://repository.ipb.ac.id/handle/123456789/62335 |
| Appears in Collections: | UT - Agricultural and Biosystem Engineering |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| F10yok.pdf Restricted Access | full text | 13.94 MB | Adobe PDF | View/Open |
| BAB I Pendahuluan.pdf Restricted Access | BAB I | 534.71 kB | Adobe PDF | View/Open |
| BAB II Tinjauan Pustaka.pdf Restricted Access | BAB II | 3.87 MB | Adobe PDF | View/Open |
| BAB III Metode Penelitian.pdf Restricted Access | BAB III | 1.59 MB | Adobe PDF | View/Open |
| BAB IV Hasil dan Pembahasan.pdf Restricted Access | BAB IV | 5.72 MB | Adobe PDF | View/Open |
| BAB V Kesimpulan dan Saran.pdf Restricted Access | BAB V | 384.8 kB | Adobe PDF | View/Open |
| Cover.pdf Restricted Access | Cover | 332.76 kB | Adobe PDF | View/Open |
| Daftar Pustaka.pdf Restricted Access | Daftar Pustaka | 469.07 kB | Adobe PDF | View/Open |
| Lampiran.pdf Restricted Access | Lampiran | 1.51 MB | Adobe PDF | View/Open |
| Ringkasan.pdf Restricted Access | Ringkasan | 521.13 kB | Adobe PDF | View/Open |