dc.description.abstractCage has a very important role in accommodating all livestock activities .1\Ifh as providing comfort and protection from environmental 'hi1-l.uences. Livestock will be able to develop and grow normally in good cage environment condition. Livestock development is influenced by the climate of the ~ge microenvironment such as air temperature, humidity, wind speed, and light j tensity. ~ This research aimed to analyze the distribution of temperature, humidity, "S!ind speed and air flow patterns inside the cage with the fan turning on and off ~ith a technique of Computational Fluid Dynamics (CFD). The parameteres ~hich were observed included temperature, relative humadity (RH), air flow and iradiation with the uniform environmental conditions from 07.00 a.m. until 15:00 l-m. Then, the data obtained were analyzed and compared with simulation results esing SolidWork 2009. "tI The highest temperature inside the cage based on measurement was 33.33 ~ at 12.00 p.m., with the simulation results using SolidWork 2009 up to 34.45 t . Error of temperature based on measurement results with simulation results at gg .OO, 12.00 and 15.00 were 5.24%, 2.83%, and 2.01%. pThe highest relative itmidity based on measurements was 89.67% in the morning and evening, during &., e simulation up to 85.17% at 08.00 p.m. RH errors from the measurement results with simulations were 2.97%, 5.07%, and 3.93%. The highest wind speed from CFD simulation results was 1.90 m/sec at 15.00 p.m. The simulation results showed that the temperature level and RH when the fan was on and off were almost the same, with the difference about ± 0.01 DC, and the air movement had a difference of about 0.02-0.11 m/sec.en
dc.subjectBogor Agricultural University (IPB)en
dc.subjectMicro Climateen
dc.subjectGarut Sheepen
dc.subjectFattening Cageen
dc.subjectCFD,en
dc.titleAnalisis Lingkungan Mikro Dengan Teknik Computational Fluid Dynamics (CFD) pada Kandang Domba Garut Sistem Tertutup di Kandang Penggemukan Fakultas Peternakan IPBen
Appears in Collections:UT - Agricultural and Biosystem Engineering

Files in This Item:
File Description SizeFormat 
F10yok.pdf
  Restricted Access
full text13.94 MBAdobe PDFView/Open
BAB I Pendahuluan.pdf
  Restricted Access
BAB I534.71 kBAdobe PDFView/Open
BAB II Tinjauan Pustaka.pdf
  Restricted Access
BAB II3.87 MBAdobe PDFView/Open
BAB III Metode Penelitian.pdf
  Restricted Access
BAB III1.59 MBAdobe PDFView/Open
BAB IV Hasil dan Pembahasan.pdf
  Restricted Access
BAB IV5.72 MBAdobe PDFView/Open
BAB V Kesimpulan dan Saran.pdf
  Restricted Access
BAB V384.8 kBAdobe PDFView/Open
Cover.pdf
  Restricted Access
Cover332.76 kBAdobe PDFView/Open
Daftar Pustaka.pdf
  Restricted Access
Daftar Pustaka469.07 kBAdobe PDFView/Open
Lampiran.pdf
  Restricted Access
Lampiran1.51 MBAdobe PDFView/Open
Ringkasan.pdf
  Restricted Access
Ringkasan521.13 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.