| dc.description.abstract | An automatic detector of water level with sensor UGN3505 as detector of changes water level has been successfully be made for this research. Sensor UGN3505 is a hall effect sensor which works based on the large magnetic fields on the surface. The output voltage generated by the sensor without the influence of a magnetic field is 2,525 volts, the output voltage is different than it should be 0.025 volts is 2.50. This shows that the sensor is not completely free from magnetic field sources, there is still the effect of the Earth's magnetic field to the sensor. Sensor output voltage will increase, with increasing magnetic field on the surface of the sensor. As the central data processing equipment, used microcontroller ATmega16. The input of microcontroller is the changes output voltage of sensor than has been converted into digital data (internal ADC ATmega16) caused the changes of magnetic field. The digital data are readable by microcontroller be processed and displayed in the 16x2 LCD, LED indicator and buzzer. Programs created using software tools CVAVR with C + + language. | en |