Show simple item record

dc.contributor.advisorSiskandar, Ridwan
dc.contributor.authorSabillah, Chika Hayya
dc.date.accessioned2026-08-11T06:32:35Z
dc.date.available2026-08-11T06:32:35Z
dc.date.issued2026
dc.identifier.urihttp://repository.ipb.ac.id/handle/123456789/178212
dc.description.abstractTerminal listrik konvensional masih bersifat pasif karena hanya berfungsi sebagai penyalur daya tanpa menyediakan pemantauan energi dan kendali beban jarak jauh. Penelitian ini bertujuan merancang dan mengimplementasikan Smartura sebagai terminal listrik pintar berbasis Internet of Things yang terintegrasi dengan ESP32, Firebase, dan website pada sistem kelistrikan AC 220 V / 50 Hz. Sistem dirancang untuk melakukan kendali on/off, pemantauan tegangan, arus, estimasi daya, informasi total energi dan informasi estimasi biaya, serta proteksi overload. Hasil pengumpulan data pada tanggal 5-11 Juni 2026 menghasilkan 6.193 data dengan rata-rata tegangan 213,15 V, rata-rata arus 0,164 A, rata-rata daya 35,07 W, total estimasi energi 3,62 kWh, dan estimasi biaya sebesar Rp5.229,29. Hasil validasi menunjukkan nilai MAPE sensor tegangan sangat baik sebesar 1,69% dan nilai sensor arus cukup baik sebesar 12,38%. Sistem juga dapat menjalankan kendali relay melalui dashboard dan memutus beban secara otomatis ketika kondisi overload terdeteksi. Dengan demikian, Smartura dapat digunakan sebagai prototipe terminal listrik pintar untuk pemantauan energi dan kendali beban listrik sederhana.
dc.description.abstractConventional electrical terminals are still passive because they only function as power distributors without providing energy monitoring and remote load control. This research aims to design and implement Smartura as a smart electrical terminal based on the Internet of Things, integrated with ESP32, Firebase, and a website on a 220 V / 50 Hz AC electrical system. The system is designed to perform on/off control, voltage monitoring, current monitoring, power estimation, total energy information, cost estimation information, and overload protection. Data collection from June 5 to June 11, 2026, resulted in 6,193 data points with an average voltage of 213.15 V, an average current of 0.164 A, an average power of 35.07 W, a total estimated energy of 3.62 kWh, and an estimated cost of Rp5,229.29. Validation results show a very good MAPE value of 1.69% for the voltage sensor and a fairly good value of 12.38% for the current sensor. The system can also perform relay control thru the dashboard and automatically disconnect the load when an overload condition is detected. Thus, Smartura can be used as a prototype of a smart electrical terminal for energy monitoring and simple electrical load control.
dc.description.sponsorship
dc.language.isoid
dc.publisherIPB Universityid
dc.titleSmartura: Perancangan Terminal Listrik Pintar dengan Pemantauan Energi dan Kendali Bebanid
dc.title.alternativeSmartura: Design of a Smart Electrical Terminal with Energy Monitoring and Load Control
dc.typeTugas Akhir
dc.subject.keywordenergy monitoringid
dc.subject.keywordinternet of thingsid
dc.subject.keywordload controlid
dc.subject.keywordoverload protectionid
dc.subject.keywordsmart electrical terminalid
dc.subtypeUndergraduate Theses