Show simple item record

dc.contributor.advisorYani, Sitti
dc.contributor.advisorPuspita, R. Tony Ibnu Sumaryada Wijaya
dc.contributor.authorDwiyanto, Tomy
dc.date.accessioned2024-08-13T12:50:02Z
dc.date.available2024-08-13T12:50:02Z
dc.date.issued2024
dc.identifier.urihttp://repository.ipb.ac.id/handle/123456789/157296
dc.description.abstractPenelitian ini bertujuan untuk mengetahui perbandingan distribusi dosis dengan penambahan radiosensitizer pada fantom kanker yang menggunakan dengan dan tanpa flattening filter (Linac FF dan FFF). Radiosensitizer yang disimulasikan adalah Au, Ag dan Pt dengan presentase bobot 2%, 4%, 6%, 8% dan 10% yang dicampurkan dengan material jaringan. Software EGSnrc digunakan untuk melakukan simulasi Monte Carlo pada fantom inhomogen berisi air dan jaringan yang dicampurkan dengan radiosensitizer yang berukuran 40×40 cm2. Hasil menunjukkan peningkatan dosis pada FFF dengan penambahan radiosensitizer. Hasil penelitian ini menunjukkan bahwa dosis yang diserap oleh jaringan yang ditambahkan radiosensitizer Au, Ag dan Pt mengalami penurunan dosis serap baik pada Linac dengan dan tanpa FF. DER yang dihasilkan menunjukkan Pt memiliki persentase yang lebih besar yang ditunjukkan juga oleh kurva yang lebih dalam pada bagian target. Pada konsentrasi yang lebih tinggi, DER pada target mengalami kenaikan yang ditandai oleh kurva PDD yang lebih curam.
dc.description.abstractThis study was aimed to determine the comparison of dose distribution with the addition of radiosensitizers to cancer phantoms using Linac with and without flattening filters (FF). Radiosensitizers simulated are Au, Ag and Pt with a weight percentage of 2%, 4%, 6%, 8% and 10% mixed with tissue material. EGSnrc software is used to perform Monte Carlo simulations on an inhomogeneous phantom containing water and tissue mixed with radiosensitizers measuring 40×40 cm2. The results showed an increase in dose to the FFF with the addition of radiosensitizers. The results of this study indicate that the dose absorbed by tissues added with Au, Ag and Pt radiosensitizers has decreased in absorbed dose both on Linac with and without FF. The resulting DER shows Pt has a larger percentage which is also indicated by a deeper curve in the target section. At higher concentrations, the DER of the target increases, which is characterized by a steeper PDD curve.
dc.description.sponsorship
dc.language.isoid
dc.publisherIPB Universityid
dc.titleSimulasi Monte Carlo Perbandingan Distribusi Dosis Radioterapi Kanker Dengan Variasi Jenis dan Konsentrasi Radiosensitizerid
dc.title.alternative
dc.typeSkripsi
dc.subject.keywordMonte Carloid
dc.subject.keywordLinac FFFid
dc.subject.keywordRadiosensitizerid


Files in this item

Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record