Show simple item record

dc.contributor.advisorHidayat, Agung Prayudha
dc.contributor.authorSURURI, RIZQI MABUL
dc.date.accessioned2024-07-22T01:03:02Z
dc.date.available2024-07-22T01:03:02Z
dc.date.issued2024
dc.identifier.urihttp://repository.ipb.ac.id/handle/123456789/154430
dc.description.abstractRIZQI MABUL SURURI. Identifikasi Defect Pin Menutup Pada Produk Timer H3CR menggunakan Failure Mode and Effect Analysis (FMEA). Dibimbing oleh AGUNG PRAYUDHA HIDAYAT. Identifikasi permasalahan defect Pin Menutup pada departemen IAB line satu H3CR dilatarbelarbelakangi dengan banyaknya penemuan defect pin menutup dalam kurun waktu Januari – Oktober 2023, defect ini menyebabkan kerugian yang cukup besar yaitu banyaknya part produk yang terdisposal sejumlah 3591 part. Part yang terdisposal diataranya base assy, PWB, dan lead wire. Berdasarkan permasalahan tersebut tujuan dari penelitian ini adalah melakukan identifikasi penyebab munculnya defect pin menutup dan merumuskan alternative solusi untuk meminimalkan munculnya defect. Pengidentifikasian penyebab permasalahan menggunakan metode diagram pareto, fish bone analysis,dan failure mode and effect analysis (FMEA). ketiga metode tersebut digunakan dalam melakukan identifikasi penyebab munculnya defect yang paling berpotensi, yang selanjutnya akan dijadikan penentuan dan pengambilan tindakan serta usulan perbaikan/maintenance. Sedangkan metode yang digunakan untuk merencanakan alernatif solusi yaitu pendekatan kaizen 5W+1H yang mempertimbangkan aspek what, when, where, why, who, dan how. Kata kunci: Failure Mode and Effect Analysis (FMEA), Identifikasi defect, Seven tools
dc.description.abstractRIZQI MABUL SURURI. Identification of Pin Closing Defects in H3CR Timer Products using Failure Mode and Effect Analysis (FMEA). Supervised by AGUNG PRAYUDHA HIDAYAT Identifying the pin-closing defect problem in the IAB line one H3CR department is motivated by the many discoveries of closing pin defects in January - October 2023. This defect causes considerable losses, namely the number of product parts disposed of in the amount of 3591 parts. Disposed parts include base assembly, PWB, and lead wire. Based on these problems, the purpose of this study is to identify the causes of the appearance of pin-closing defects and formulate alternative solutions to minimize the appearance of defects. The three methods are used to identify the causes of the appearance of the most potential defects, which will then be prioritized in taking and determining actions and maintenance recommendations. The method used to plan alternative solutions is the 5W+1H kaizen approach, which considers aspects of what, when, where, why, who, and how. Keywords: Defect identification, Failure Mode and Effect Analysis (FMEA), Seven tools
dc.description.sponsorship
dc.language.isoid
dc.publisherIPB Universityid
dc.titleIdentifikasi Defect Pin Menutup Pada Produk Timer H3CR Menggunakan Failure Mode and Effect Analysis (FMEA)id
dc.title.alternativeIdentification of Pin Closing Defects in H3CR Timer Products Using Failure Mode and Effect Analysis (FMEA)
dc.typeTugas Akhir
dc.subject.keywordseven toolsid
dc.subject.keywordFailure Mode and Effect Analysis (FMEA)id
dc.subject.keywordIdentifikasi defectid