Show simple item record

dc.contributor.advisorSulistijorini
dc.contributor.authorHERDIAN, YOVI
dc.date.accessioned2024-07-17T02:34:58Z
dc.date.available2024-07-17T02:34:58Z
dc.date.issued2024
dc.identifier.urihttp://repository.ipb.ac.id/handle/123456789/153920
dc.description.abstractIndustri pengolahan limbah bahan berbahaya dan beracun (LB3) merupakan industri yang berperan dalam menyediakan jasa pengelolaan dan pengolahan LB3. Salah satu bentuk pemantauan untuk pendeteksi kebocoran pada landfill yaitu adanya underdrainase landfill.Analisis terhadap kualitas air bersih pada underdrainase berfungsi untuk mengetahui potensi pemanfaatan air yang sesuai dengan kelas peruntukannya. Belum optimalnya pemanfaatan air underdrainase sehingga prinsip pengolahan yang berkelanjutan belum terlaksana dengan baik. Pengambilan data dilakukan pada empat titik pengamatan yang mewakili kondisi air underdrainase aktif dan tidak aktif yaitu UD X1, UD X2, UD X3 dan UD X4. Pengujian kualitas air menggunakan metode storet. Hasil pengukuran pada keempat titik pengamatan menunjukkan bahwa terdapat beberapa parameter yang melebihi baku mutu. Parameter yang berada dalam tingkat pencemar tinggi meliputi suhu, amonia, pb dan Hg berada di atas baku mutu kelas I, II, III dan kelas IV. Air underdrainase memiliki potensi untuk dimanfaatkan yaitu pada kelas peruntukkan kelas III dan kelas IV dengan syarat harus melewati treatment pengolahan untuk penurunan suhu, amonia dan kadar logam.
dc.description.abstractThe hazardous and toxic waste (LB3) processing industry is an industry that plays a role in provides LB3 management and processing services. One form of monitoring for leak detection in landfills is the presence of landfill underdrainage. Analysis of the quality of clean water in the underdrainage serves to determine the potential utilization of water in accordance with its desigantion class. The utilization of underdrainage water has not been optimal so that the principle of sustainable processing has not been implemented properly. Data collection was carried out at four observation points representing active and inactive underdrainage water conditions, namely UD X1, UD X2, UD X3 and UD X4. Water quality testing uses the storet method. The measurement results at the four observation points show that there are several parameters that exceed the quality standards. Parameters that are in a high level of pollution include temperature, ammonia, pb and Hg are above the quality standards of class I,II, III, and class IV. Underdrainage water has the potential to be utilized, namely in class III and class IV designation classes on condition that it must pass processing treatment to reduce temperature, ammonia and metal levels
dc.description.sponsorship
dc.language.isoid
dc.publisherIPB Universityid
dc.titlePOTENSI PEMANFAATAN AIR UNDERDRAINASE LANDFILL DI INDUSTRI PENGOLAHAN LIMBAH BAHAN BERBAHAYA DAN BERACUNid
dc.title.alternativePotential Utilization of Landfill Underdrainage Water in the Hazardous and Toxic Waste Treatment Industry
dc.typeTugas Akhir
dc.subject.keywordammoniaid
dc.subject.keywordammoniaid
dc.subject.keywordlandfillid
dc.subject.keywordlogamid
dc.subject.keywordmetode storetid
dc.subject.keywordlandfillid
dc.subject.keywordmetalsid
dc.subject.keywordmethod storetid