dc.description.abstractPerbandingan volume fase padat, cair, dan gas pada tanah merupakan hal yang penting karena mempengaruhi sifat fisik tanah dan pertumbuhan tanaman. Total volume fase padat dan cair tanah disebut sebagai volume aktual. Bila volume aktual diketahui, sifat-sifat fisik dasar tanah dapat diperoleh dengan sangat sederhana dan sistematis. Salah satu sifat fisik yang dapat ditentukan adalah kadar air. Alat ukur volume tanah yang sudah sering digunakan adalah Three Phase Meter OSK 10014R Serial No.1855 Ogawa seiki. Namun, alat tersebut memiliki harga yang cukup mahal. Oleh karena itu, dibuat alternatif alat lain dengan prinsip yang sama dan harga yang lebih terjangkau, yang disebut Three Phase Meter sederhana. Penelitian ini bertujuan menguji ketelitian serta ketepatan alat Three Phase Meter sederhana untuk pengukuran volume aktual pada tanah gambut dengan menerapkan prinsip hukum Boyle. Alat diuji menggunakan sampel benda padat volume 0 ml, 30 ml, 50 ml, dan 80 ml sebagai standar. Sampel dimasukkan ke dalam tabung alat, lalu ditambahkan udara melalui syringe sehingga tekanan udara di dalam tabung mencapai 8 kPa. Setelah berhasil diuji menggunakan standar, alat diuji dengan contoh tanah gambut utuh dalam ring sampler berukuran 100 cm3. Pengujian ketelitian dilakukan dengan cara pengukuran 5 kali ulangan, sedangkan ketepatan diketahui dengan membandingkan hasil pengukuran dengan hasil teoritis. Volume aktual tanah gambut yang didapatkan dari pengukuran menunjukkan hasil yang tidak jauh berbeda pada antar ulangan. Hasil pengujian ketelitian alat menunjukkan rata-rata nilai sebesar 99.5%. Hasil pengukuran alat dan teoritis menunjukkan nilai rata-rata ketepatan sebesar 97.9% dengan nilai kesalahan relatif kecil, yaitu sebesar 2.1%. Nilai tersebut menunjukkan bahwa pengukuran menggunakan Three Phase Meter sederhana memiliki ketepatan yang tinggi karena nilai pengukuran dengan alat mendekati nilai teoritis. Dengan demikian, alat Three Phase Meter sederhana layak digunakan untuk mengukur volume aktual pada tanah.id
dc.description.abstractThe volume ratio of the solid, liquid, and gas phases of soil is important because it shows the physical properties of soil and affects plant growth. The total volume of solid and liquid phases of soil is referred to the actual volume. When the actual volume is known, the basic physical properties of soil can be obtained simply and systematically, such as water content. The common instrument which is used for measuring soil volume is Three Phase Meter OSK 10014R Serial No.1855 Ogawa Seiki. However, the instrument is quite expensive, therefore, an alternative instrument with same principle and more affordable price was created, called a simple Three Phase Meter. This study aimed to test the performance, such as the accuracy and the precision of the simple Three Phase Meter with the application of Boyle's law principle, to measure the actual volume of peat soil. The instrument was tested using solid samples with volumes of 0 ml, 30 ml, 50 ml, and 80 ml as standards. The sample was inserted into the instrument tube and then air was added through syringe so that the air pressure in the tube reached 8 kPa. After successfully testing the solid samples, the instrument was tested with samples of peat soil in a ring sampler measuring 100 cm3. The instrument precision was known by repeating the measurement five times, while the accuracy was known by comparing the measurement results with the theoretical results. The actual volume of peat soil obtained from the measurements result showed that there were not much different between replicates. The instrument's precision test results showed an average value of 99.5%. The instrument and theoretical measurements show an average accuracy value of 97.9%, with a relatively small error value of 2.1%. The value indicated that the measurement using a simple Three Phase Meter has high accuracy because it is close to the theoretical value. Thus, a simple Three Phase Meter is feasible to measure the actual volume of the soil.id
dc.language.isoidid
dc.publisherIPB Universityid
dc.titleUji Kinerja Alat Ukur Volume Tanah dengan Prinsip Tekanan Udaraid
dc.title.alternativePerformance Test of Soil Volume Measurement Instrument with Air Pressure Principleid
dc.typeUndergraduate Thesisid
dc.subject.keywordgambutid
dc.subject.keywordkadar airid
dc.subject.keywordtekanan udaraid
dc.subject.keywordThree Phase Meterid
dc.subject.keywordvolume aktualid