Please use this identifier to cite or link to this item: http://repository.ipb.ac.id/handle/123456789/168935
Title: Evaluasi Efektivitas Sanitasi Mesin Filling Tube Krimer Kental Manis di PT XYZ Menggunakan Pendekatan PDCA
Other Titles: 
Authors: Budi, Faleh Setia
MERYASARI, SYIVANA
Issue Date: 2025
Publisher: IPB University
Abstract: Krimer Kental Manis (KKM) merupakan produk turunan susu yang banyak digunakan dalam makanan dan minuman. PT XYZ selaku produsen KKM menerima keluhan terkait produk krimer kental manis kemasan sachet menggembung, yang mengindikasikan adanya pertumbuhan mikroorganisme. Berdasarkan analisis diagram Ishikawa, penyebab utama penggembungan diidentifikasi karena frekuensi sanitasi mesin filling tube yang kurang optimal. Penelitian ini bertujuan untuk mengevaluasi efektivitas pembersihan mesin filling tube pasca pembersihan, serta menentukan interval pembersihan ulang yang ideal untuk menekan pertumbuhan mikroba sebelum siklus CIP (Cleaning in Place) berikutnya. Metode yang digunakan adalah siklus PDCA (Plan-Do-Check-Action) dengan pengambilan data melalui metode swab, menggunakan parameter mikrobiologi, yaitu Total Plate Count (TPC), Coliform, serta kapang dan khamir. Hasil penelitian menunjukkan bahwa sejak hari ketiga pasca CIP, terjadi peningkatan signifikan mikroorganisme, dengan TPC mencapai 1,82 × 10² ± 6,25 × 10¹ CFU/ 100 cm² dan kapang khamir sebesar 1,16 × 10¹ ± 0,00 CFU/100 cm². Hasil tersebut melebihi standar internal perusahaan, yaitu 1,0 × 10² untuk TPC dan 1,0 × 10¹ untuk kapang khamir. Hasil tersebut menunjukkan bahwa interval pembersihan saat ini belum optimal dan perlu disesuaikan dan dilakukan tindakan perbaikan.
Sweetened Condensed Creamer (SCC) is a dairy-derived product widely used in food and beverages. PT XYZ, as the manufacturer of SCC, received complaints regarding bloated sachet-packaged products, indicating potential microbial growth. Based on an Ishikawa diagram analysis, the primary cause of the bloating was identified as suboptimal sanitation frequency of the filling tube machine. This study aimed to evaluate the effectiveness of filling tube cleaning post-CIP (Cleaning in Place) and to determine the ideal cleaning interval to suppress microbial growth before the subsequent CIP cycle. The research employed the PDCA (Plan-Do-Check-Action) cycle and utilized the swab method for data collection, using microbiological parameters including Total Plate Count (TPC), coliforms and molds yeasts. The results indicated a significant increase in microbial counts starting from the third day after CIP, with TPC reaching 1.82 × 10² ± 6.25 × 10¹ CFU/100 cm² and mold and yeast counts of 1.16 × 10¹ ± 0.00 CFU/100 cm². These values exceeded the company’s internal standards of 1.0 × 10² for TPC and 1.0 × 10¹ for mold and yeast. The findings suggest that the current cleaning interval is not optimal and requires adjustment and corrective action.
URI: http://repository.ipb.ac.id/handle/123456789/168935
Appears in Collections:UT - Food Science and Technology

Files in This Item:
File Description SizeFormat 
cover_F2401211045_1deca79134574e32bfc09278a5b7afcd.pdfCover997.25 kBAdobe PDFView/Open
fulltext_F2401211045_bf731d91750942848b941a046fd3bbdc.pdf
  Restricted Access
Fulltext1.14 MBAdobe PDFView/Open
lampiran_F2401211045_eb60d18d91b84a4185e827eac181d30f.pdf
  Restricted Access
Lampiran1 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.