dc.contributor.author | Nurullaeli | |
dc.contributor.author | Kartono, Agus | |
dc.contributor.author | Dahlan | |
dc.date.accessioned | 2015-08-07T03:33:16Z | |
dc.date.available | 2015-08-07T03:33:16Z | |
dc.date.issued | 2013 | |
dc.identifier.issn | 0972-0871 | |
dc.identifier.uri | http://repository.ipb.ac.id/handle/123456789/75944 | |
dc.description.abstract | The modified minimal model of glucose and insulin plasma levels .is common I y us~~ d to analyze the res· ults of glucose tolerance. .t ests 111 humans. In this paper. a mathematical model for dcscnh111g the lucose infusion rate is introduced. The modified minimal model was ~sed to study a few sets of published data including healthy humans and type 2 diabetes. The gluc0se-i nsulin system is a dynamic integrated physiological system and gcneratcs the rcal opt11m~ed model parameters from the experimental data using the 111od1hed m1·1 1·1 1na 1 mod c·1 . ·1·hc avcra,o, ed R~ va lue between measured and calculated plasma concentrations is 0.977. which indicates excellent agreement. | en |
dc.language.iso | en | |
dc.publisher | Pushpa Publishing House, Allnhnbad, India | |
dc.relation.ispartofseries | Volume 2013,;Part VI. Pages 587-596 | |
dc.title | Mathematical Model Of The Intra Venous Glucose Tolerance Test Using Modified Minimal Model | en |
dc.type | Article | en |
dc.subject.keyword | modified minimal model | en |
dc.subject.keyword | intravenous glucose tolerance test | en |
dc.subject.keyword | glucoscinsulin system | en |