View Item 
      •   IPB Repository
      • Dissertations and Theses
      • Master Theses
      • MT - Mathematics and Natural Science
      • View Item
      •   IPB Repository
      • Dissertations and Theses
      • Master Theses
      • MT - Mathematics and Natural Science
      • View Item
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      Pendugaan Model Rancangan Campuran-Campuran dengan Petak Terbagi

      Model Estimation of Mixture-Mixture Design using Split Plot

      Thumbnail
      View/Open
      full text (727.8Kb)
      Abstract (323.4Kb)
      BAB I (320.6Kb)
      BAB II (431.0Kb)
      BAB III (411.2Kb)
      BAB IV (485.8Kb)
      BAB V (320.9Kb)
      Cover (320.5Kb)
      Daftar Pustaka (317.0Kb)
      Lampiran (473.9Kb)
      Date
      2010
      Author
      Andriyati, Ani
      Wigena, Aji Hamim
      Syafitri, Utami Dyah
      Metadata
      Show full item record
      Abstract
      Prosedur sidik jari kromatografi merupakan suatu pendekatan efektif untuk mengontrol kualitas obat herbal. Optimisasi sidik jari kromatografi diperoleh melalui optimisasi faktor pelarut ekstraksi dan faktor fase gerak kromatografi cair kinerja tingkat tinggi (KCKT). Prosedur sidik jari dilakukan untuk mengetahui komposisi yang tepat dari campuran ekstraksi dan campuran fase gerak kromatografi.
       
      Mixture-mixture design with a split plot was proposed for simultaneously two mixture systems. The complete model was formed by multiplying cubic models for two systems. The design was applied to the simultaneous optimizations of both mobile phase chromatographic mixtures and extraction mixture for the Phyllanthus niruri L. In this experiment used split plot approach. Saturated model coefficients were hypothesized with confident interval 99%. Reduction model consisted of real coefficients in complete coefficient models. Estimation method of reduction model coefficients consisted of Ordinary Least Square (OLS) and Generalized Least Square (GLS). Models were formed to count sum peaks chromatographic at 225, 254, and 260 nm. RMSEP values in OLS method at wavelength 225, 254, and 260 nm were produced 4.122, 3.049, and 2.56, otherwise RMSEP values in GLS method were 3.99, 2.79, and 3.18. There are component indicators in wavelength greater and more complex. The GLS method was better than OLS method based on simulation error of variance ratio 0.2 up to 0.3.
       
      URI
      http://repository.ipb.ac.id/handle/123456789/55947
      Collections
      • MT - Mathematics and Natural Science [4149]

      Copyright © 2020 Library of IPB University
      All rights reserved
      Contact Us | Send Feedback
      Indonesia DSpace Group 
      IPB University Scientific Repository
      UIN Syarif Hidayatullah Institutional Repository
      Universitas Jember Digital Repository
        

       

      Browse

      All of IPB RepositoryCollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

      My Account

      Login

      Application

      google store

      Copyright © 2020 Library of IPB University
      All rights reserved
      Contact Us | Send Feedback
      Indonesia DSpace Group 
      IPB University Scientific Repository
      UIN Syarif Hidayatullah Institutional Repository
      Universitas Jember Digital Repository