Please use this identifier to cite or link to this item:
http://repository.ipb.ac.id/handle/123456789/25738Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Elphyson T. | |
| dc.contributor.author | Pandjaitan, Nora H. | |
| dc.contributor.author | Prastowo | |
| dc.date.accessioned | 2010-05-26T04:38:09Z | |
| dc.date.available | 2010-05-26T04:38:09Z | |
| dc.date.issued | 2000 | |
| dc.identifier.uri | http://repository.ipb.ac.id/handle/123456789/25738 | |
| dc.description.abstract | Trickle Irrigation is an irrigation method which can give continuou.~ water drops at [he root zone. The muin conzponexts of Trickle Irrigation .Jlv.r.tenz are : etnilter, lateral pipe, nlan(fi1d ,7@e, main pipe, water pun~p and other supporting components. This design is trsing point source type of emitter. Each emitter serves 3 pepper plants. The total power consumption at pump station I is 6.6 kW, trt y utnp station 11 is 4.4 k W and at ptrmy station 111 is 8.3 kW. The total operatiorz of pump station I is 752.1 hrs/ season, pump station 11 is 2256.2 hrs / season and putnp .sfaifo n Ill i.s 1504.1 hrs / season. | id |
| dc.publisher | IPB (Bogor Agricultural University) | |
| dc.title | Design of Trickle Irrigation System for Peppers (Capsicum annum var. longum L.) at Resinda Project, Karawang | id |
| Appears in Collections: | Mechanical & Biosystem Engineering | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| Elphyson T (Heri).pdf | Publications | 1.4 MB | Adobe PDF | ![]() View/Open |