Please use this identifier to cite or link to this item:
http://repository.ipb.ac.id/handle/123456789/169625| Title: | Penentuan Kadar Zink Limbah Lumpur Industri pada Instalasi Pengolahan Air Limbah secara Spektrofotometer Serapan Atom |
| Other Titles: | |
| Authors: | Wulanawati, Armi Jayanti, Jenny |
| Issue Date: | 2025 |
| Publisher: | IPB University |
| Abstract: | Evaluasi efektivitas pengolahan lumpur IPAL dari industri pelapisan logam
dan tekstil dilakukan melalui analisis kadar Zn total, potensi pelindian
menggunakan metode TCLP, serta validasi metode analisis. Kadar Zn total
mengalami penurunan signifikan, dari 142,11 menjadi 43,44 mg/kg (pelapisan
logam) dan dari 408,19 menjadi 80,9 mg/kg (tekstil). Uji TCLP menunjukkan
penurunan potensi pelindian Zn dari 3,40 menjadi 1,32 mg/L dan dari 8,62 menjadi
2,15 mg/L, yang mengindikasikan berkurangnya mobilitas logam setelah
pengolahan. Perubahan bentuk lumpur dari kondisi basah menjadi padat dan kering
mendukung dugaan terjadinya dehidrasi dan transformasi termal. Validasi metode
analisis Zn memberikan hasil yang memenuhi syarat AOAC 2016, ditunjukkan oleh
nilai linearitas r = 0,9995, %RSD = 0,33%, akurasi 99,84–100,99%, serta ketahanan
dan ketangguhan yang diterima. Secara keseluruhan, hasil menunjukkan bahwa
metode analisis yang digunakan valid, dan proses pengolahan lumpur efektif dalam
menurunkan kadar dan potensi pelindian zink. The effectiveness of sludge treatment from wastewater treatment plants (WWTP) in metal plating and textile industries was evaluated through total Zn content analysis, leaching potential using the TCLP method, and analytical method validation. The total Zn concentration showed a significant decrease, from 142.11 to 43.44 mg/kg (metal plating) and from 408.19 to 80.9 mg/kg (textile). TCLP tests indicated a reduction in Zn leaching potential from 3.40 to 1.32 mg/L and from 8.62 to 2.15 mg/L, indicating decreased metal mobility after treatment. The transformation of sludge from wet to dry and solid form supported the assumption of dehydration and thermal transformation. The validation of Zn analytical method yielded results in accordance with AOAC 2016 standards, as shown by linearity value r = 0.9995, %RSD = 0.33%, accuracy of 99.84–100.99%, and acceptable robustness and ruggedness. Overall, the results confirmed that the analytical method was valid and the sludge treatment process was effective in reducing Zn levels and leaching potential. |
| URI: | http://repository.ipb.ac.id/handle/123456789/169625 |
| Appears in Collections: | UT - Chemistry Analysis |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| cover_J0312211062_8b5efdfb29374d3481f22d53f0a692eb.pdf | Cover | 2.33 MB | Adobe PDF | View/Open |
| fulltext_J0312211062_7bf5a2eb5fe9414e9c9190a75cd849d1.pdf Restricted Access | Fulltext | 2.9 MB | Adobe PDF | View/Open |
| lampiran_J0312211062_f7081794399b4220b391a54621acbf27.pdf Restricted Access | Lampiran | 4.59 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.