dc.identifier.urihttp://repository.ipb.ac.id/handle/123456789/169112-
dc.description.abstractPengendalian kualitas produk di PT Pupuk Kujang Cikampek dilakukan melalui analisis rutin dengan jaminan mutu internal untuk memastikan keandalan hasil. Penelitian ini bertujuan membuat serta mengevaluasi sampel kontrol (SC) urea berdasarkan uji akurasi, presisi, homogenitas, dan stabilitas, serta konsistensinya terhadap instrumen berbeda merek. Analisis kadar biuret dilakukan dengan metode spektrofotometri, sedangkan total nitrogen (N) dengan metode Kjeldahl. Hasil menunjukkan metode akurat dengan perolehan kembali 99–100% dan sesuai rentang nilai benar bahan acuan KBA. Presisi baik ditunjukkan oleh SBR = 2,7% untuk biuret dan = 1,6% total N. SC urea dinyatakan homogen (Ss = 0,3s) dan stabil (|Xr - Yr| = 0,3s). Nilai properti SC ditetapkan dengan rentang biuret sebesar 1,04–1,16%b/b (SPF 12.13) dan 1,05–1,17%b/b (SPF 12.14), serta total N sebesar 46,05–46,55%b/b (NIT 13.04 dan 15.05). Pemantauan hasil analisis selama 10 minggu menggunakan instrumen berbeda merek menunjukkan hasil konsisten tanpa pelanggaran aturan Westgard pada grafik Levey-Jennings.-
dc.description.abstractProduct quality control at PT Pupuk Kujang Cikampek is carried out through routine analysis with internal quality assurance to ensure reliable results. This study aims to develop and evaluate urea control samples (SC) based on accuracy, precision, homogeneity, and stability tests, as well as assess their consistency using instruments of different brands. Biuret content was analyzed using the spectrophotometric method, while total nitrogen (N) was measured using the Kjeldahl method. The results showed accurate methods with recoveries of 99–100% and within the certified reference material KBA range. Good precision was indicated by RSD = 2.7% for biuret and = 1.6% for total N. The SC urea was found to be homogeneous (Ss = 0.3s) and stable (|Xr - Yr| = 0.3s). Property values were set with biuret ranges of 1.04–1.16%w/w (SPF 12.13) and 1.05–1.17%w/w (SPF 12.14), and total N of 46.05–46.55%w/w (NIT 13.04 and 15.05). Analysis monitoring over 10 weeks using different branded instruments showed consistent results with no Westgard rule violations on the Levey-Jennings chart.-
dc.description.sponsorshipnull-
dc.language.isoid-
dc.publisherIPB Universityid
dc.titlePembuatan dan Pengujian Sampel Kontrol Urea sebagai Jaminan Mutu Internal dalam Analisis Kadar Biuret dan Total Nitrogen pada Pupuk Ureaid
dc.title.alternativeDevelopment and Testing of Urea Control Samples as Internal Quality Assurance in the Analysis of Biuret and Total Nitrogen Content in Urea Fertilizer-
dc.typeTugas Akhir-
dc.subject.keywordbiuretid
dc.subject.keywordjaminan mutuid
dc.subject.keywordsampel kontrol ureaid
dc.subject.keywordtotal nitrogenid
dc.subject.keywordquality assuranceid
dc.subject.keywordurea control sampleid
Appears in Collections:UT - Chemistry Analysis

Files in This Item:
File Description SizeFormat 
cover_J0312211033_1c04b310e60f438697be9e215b7688a3.pdfCover6.25 MBAdobe PDFView/Open
fulltext_J0312211033_882ad9d975554eb58d18a3debb954e28.pdf
  Restricted Access
Fulltext6.7 MBAdobe PDFView/Open
lampiran_J0312211033_f751f8d1c61944beac8c3f5b65b6e668.pdf
  Restricted Access
Lampiran2.26 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.