dc.description.abstractValidasi metode perlu dilakukan terhadap metode analisis yang dimodifikasi. Penelitian ini bertujuan memvalidasi metode analisis kadar arsen dalam susu bubuk dengan metode standar Food and Drug Administration (FDA) Edisi 1.2 Tahun 2020 tentang Elemental Analysis in Food Using Microwave Assisted Digestion yang dimodifikasi pada penggunaan larutan pendestruksi. Validasi metode menghasilkan selektivitas sebesar 75 (m/z), batas deteksi instumen (BDI) sebesar 0,0080 µg/L, batas deteksi (BD) sebesar 24,70 µg/kg dan batas kuantitasi (BK) sebesar 82,32 µg/kg. Linearitas metode menghasilkan koefisien determinasi (R2) sebesar 0,9996. Presisi keterulangan memenuhi syarat keberterimaan %SBR < 2/3 CV Horwitz dan presisi antara memenuhi syarat keberterimaan uji t. Akurasi memenuhi syarat keberterimaan %recovery berada pada rentang 80% - 120%. Metode tahan terhadap perubahan volume larutan pendestruksi dan metode tangguh terhadap perubahan hari pengukuran. Metode modifikasi dinyatakan valid untuk analisis kadar arsen dalam susu bubuk karena memenuhi seluruh syarat keberterimaan, sehingga dapat digunakan untuk metode analisis rutin.-
dc.description.abstractMethod validation needed to be carried out on the modified analysis method. This study aimed to validate the analysis method of arsenic levels in powdered milk using the standard method of the Food and Drug Administration (FDA) Edition 1.2 of 2020 concerning Elemental Analysis in Food using Microwave Assisted Digestion modified by using a destructor solution. Method validation resulted in a selectivity of 75 (m/z), an instrument detection limit (IDL) of 0.0080 µg/L, a detection limit (DL) of 24,70 µg/kg and a quantitation limit (QL) of 82,32 µg/kg. The linearity of the method resulted in a determination coefficient (R2) of 0.9996. The repeatability precision met the acceptance requirements of %SBR <2/3 CV Horwitz and the intermediate precision met the acceptance requirements of the t test. The accuracy met the acceptance requirements %recovery in the range of 80% - 120%. The method was robust to changes in the volume of the destructive solution and the method was rugged to changes in the day of measurement. The modified method was declared valid for the analysis of arsenic levels in powdered milk because it met all the acceptance requirements, so it could be used for routine analysis methods.-
dc.description.sponsorshipnull-
dc.language.isoid-
dc.publisherIPB Universityid
dc.titleValidasi Metode Analisis Kadar Arsen dalam Susu Bubuk dengan Destruksi Basah menggunakan ICP-MSid
dc.title.alternativeValidation of Arsenic Analysis Method in Powdered Milk by Wet Destruction Using ICP-MS-
dc.typeTugas Akhir-
dc.subject.keywordarsenid
dc.subject.keywordDestruksi basahid
dc.subject.keywordsusu bubukid
dc.subject.keywordvalidasi metodeid
dc.subject.keywordarsenicid
dc.subject.keywordmilk powderid
dc.subject.keywordmethod validationid
dc.subject.keywordwet digestionid
dc.subject.keywordICP-MSid
Appears in Collections:UT - Chemistry Analysis

Files in This Item:
File Description SizeFormat 
cover_J0312211063_afbbdffbd6b542e3ab9025aaa837762e.pdfCover2.44 MBAdobe PDFView/Open
fulltext_J0312211063_a8dd50edb5c54ae0af3e9454c433dca5.pdf
  Restricted Access
Fulltext2.89 MBAdobe PDFView/Open
lampiran_J0312211063_ef081da6b66c47668725974b6f0678d8.pdf
  Restricted Access
Lampiran7.01 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.