dc.description.abstractABSTRAK SAPLIAN RAHMAN PAIGO. Estimasi Ketidakpastian Pengukuran Kadar Perak pada Sampel Konsentrat Timbel secara Spektrofotometri Serapan Atom Nyala. Dibimbing oleh BUDI ARIFIN dan YESAYA APRILLIANTO. PT Ikova Amerta Indonesia adalah perusahaan swasta yang bergerak di bidang jasa laboratorium pengujian, khususnya pengujian konsentrat timbal (Pb). Konsentrat Pb diperoleh dari ekstraksi bijih galena melalui proses flotasi, yang membutuhkan pemurnian untuk memisahkan timbal dari pengotor. Pengujian estimasi ketidakpastian kadar Ag dalam konsentrat Pb merupakan salah satu rangkaian pengujian dari validasi metode untuk menghitung nilai benar dari hasil pengukuran kadar Ag dalam konsentrat Pb. Sesuai ISO 17025:2017 klausul 7.6.1, laboratorium harus mengidentifikasi kontribusi terhadap ketidakpastian pengukuran. Estimasi ketidakpastian penting untuk mengevaluasi keandalan data dan kesesuaiannya dengan tujuan penggunaan. Dalam penelitian, ketidakpastian kadar perak dalam konsentrat timbal dihitung sebesar 115 mg/kg, dengan kadar perak ditemukan sebesar 2125 mg/kg. Hasil ini memenuhi syarat keberterimaan dengan ketidakpastian relatif 5%, lebih rendah dari batas 10%. Kata kunci: Ag, estimasi ketidakpastian, konsentrat Pb, spektrofotometri SSA-nyala-
dc.description.abstractABSTRACT SAPLIAN RAHMAN PAIGO. Estimated Uncertainty in Measurement of Silver Content in Lead Concentrate Samples using Flame Atomic Absorption Spectrophotometry. Supervised by BUDI ARIFIN and YESAYA APRILLIANTO. PT Ikova Amerta Indonesia was a private company engaged in laboratory testing services, especially lead (Pb) concentrate testing. Pb concentrate was obtained from galena ore extraction through a flotation process, which required purification to separate lead from impurities. Testing the uncertainty estimation of Ag levels in Pb concentrate was one of a series of tests from method validation to calculate the true value of the measurement results of Ag levels in Pb concentrate. According to ISO 17025:2017 clause 7.6.1, the laboratory had to identify contributions to uncertainty measurement. Uncertainty estimation was important to evaluate the reliability of the data and its suitability for the intended use. In the study, the uncertainty of the silver content in lead concentrate was calculated at 115 mg/kg, with the silver content found at 2125 mg/kg. These results met the acceptance requirements with a relative uncertainty of 5%, lower than the 10% limit. Keywords: Ag, Pb concentrate, SSA-flame spectrophotometry, uncertainty estimation-
dc.description.sponsorshipnull-
dc.language.isoid-
dc.publisherIPB Universityid
dc.titleEstimasi Ketidakpastian Pengukuran Kadar Perak pada Sampel Konsentrat Timbel secara Spektrofotometri Serapan Atom Nyalaid
dc.title.alternativeEstimated Uncertainty in Measurement of Silver Content in Lead Concentrate Samples using Flame Atomic Absorption Spectrophotometry-
dc.typeTugas Akhir-
dc.subject.keywordSSA-flame spectrophotometryid
dc.subject.keywordAgid
dc.subject.keyworduncertainty estimationid
dc.subject.keywordPb concentrateid
Appears in Collections:UT - Chemistry Analysis

Files in This Item:
File Description SizeFormat 
cover_J3L118020_04c6dd79d11d457db73018a8ae87e63a.pdfCover575.03 kBAdobe PDFView/Open
fulltext_J3L118020_bcbdc30bb94e4ec592fabbe98f9cd39d.pdf
  Restricted Access
Fulltext961.25 kBAdobe PDFView/Open
lampiran_J3L118020_d6698ce407f944fa8916af15da51665b.pdf
  Restricted Access
Lampiran705.2 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.