Please use this identifier to cite or link to this item: http://repository.ipb.ac.id/handle/123456789/156450
Title: Efektivitas Penggunaaan Kolom Kromatografi Terhadap Validasi Metode Analisis Kadar Levetiracetam Menggunakan HPLC
Other Titles: The effectiveness of the use of chromatography columns over validation of the Levetiracetam rate analysis method using HPLC
Authors: Andrianto, Dimas
JANNAH, RAHMA JAUHAR
Issue Date: 2024
Publisher: IPB University
Abstract: Industri farmasi telah menerapkan metode analisis obat sesuai dengan peraturan BPOM No. 23 tahun 2022 yang mengacu pada Farmakope Indonesia (FI) 2020. Metode analisis kadar levetiracetam sebelumnya menggunakan LCMS diganti menjadi metode HPLC. Pemilihan kolom C18 yang efektif akan memberikan hasil analisis yang valid. Validasi metode tersebut dilakukan dengan parameter akurasi, presisi, spesifisitas, Limit of Detection (LOD), Limit of Quantitation (LOQ), linearitas dan rentang, serta robustness. Tujuan dari penelitian ini adalah menentukan kolom C18 yang efektif untuk validasi metode analisis kadar levetiracetam. Fase diam yang digunakan berupa kolom silica C18 (4,6 µm x 15 cm, 5 µm), fase gerak dengan elusi gradien yaitu larutan A (buffer fosfat pH 5,5: asetonitril (19:1)) dan larutan B (asetonitril), serta detektor UV 205 nm. Hasil analisis menunjukkan bahwa kolom C18 kode A3 memberikan hasil yang lebih efektif dan digunakan pada validasi metode analisis kadar levetiracetam. Simpulan penelitian ini adalah kolom A3 efektif digunakan dalam validasi metode analisis kadar levetiracetam. Uji semua parameter telah memenuhi syarat keberterimaan.
The pharmaceutical industry has implemented drug analysis methods in accordance with BPOM Regulation No. 23 of 2022 which refers to Farmakope Indonesia (FI) 2020. The previous method of analyzing levetiracetam levels using LCMS was replaced by the HPLC method. An effective selection of C18 columns will give valid analysis results. Validation of such methods is done with parameters of accuracy, precision, specificity, Limit of Detection (LOD), Limit of Quantitation (LOQ), linearity and range, and robustness. The aim of this study was to determine the effective C18 column for validating the method of analyzing levetiracetam levels. The stationary phase used is a C18 silica column (4.6 mm x 15 cm, 5 µm), a mobile phase with a gradient elusion of a solution A (pH 5.5 phosphate buffer: acetonitril (19:1)) and a solution B (acetonitril), as well as a 205 nm UV detector. The results of the analysis showed that column C18 code A3 yielded more effective results and was used in validating methods of analysis of levetiracetam levels. The conclusion of this study is that the A3 column is effective in validating the method of analyzing levetiracetam levels. All parameters have qualified for compliance.
URI: http://repository.ipb.ac.id/handle/123456789/156450
Appears in Collections:UT - Chemistry Analysis

Files in This Item:
File Description SizeFormat 
cover_J0312201062_6084b173837a42948ed9aca93cd04230.pdfCover889.96 kBAdobe PDFView/Open
fulltext_J0312201062_76d3773b501243fc83e3453f241bf1c9.pdf
  Restricted Access
Fulltext1.35 MBAdobe PDFView/Open
lampiran_J0312201062_b82f75be97bc4c0982232ae335d10d20.pdf
  Restricted Access
Lampiran871.36 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.