Please use this identifier to cite or link to this item:
http://repository.ipb.ac.id/handle/123456789/154089Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.advisor | Budiharto, Ivone Wulandari | - |
| dc.contributor.author | MAULIDA, TISA | - |
| dc.date.accessioned | 2024-07-18T01:48:58Z | - |
| dc.date.available | 2024-07-18T01:48:58Z | - |
| dc.date.issued | 2024 | - |
| dc.identifier.uri | http://repository.ipb.ac.id/handle/123456789/154089 | - |
| dc.description.abstract | Pengecekan kualitas air dan penentuan dosis optimum koagulan PAC (Poly Aluminium Chloride) serta polimer kationik merupakan komponen pokok yang diperlukan dalam penyusunan standar operasional prosedur (SOP) dalam pengolahan air sungai Ciujung yang memiliki karakteristik tingginya nilai kekeruhan. Pengujian menggunakan metode jar test yang mengacu pada SNI 19- 6449-2000 dengan penilaian keoptimalan dosis berdasarkan presentase efektivitas penyisihan kekeruhan dan stabiltas pH serta TDS. Berdasarkan hasil penelitian yang dilakukan pada variasi kekeruhan 50-60 NTU, 70-90 NTU, 100-200 NTU dan 400-600 NTU dosis PAC optimum pada rentang 90-110 ppm dan dosis 0,3-0,4 ppm untuk penggunaan polimer kationik dengan kecepatan pengadukan lambat optimal pada 50 rpm. Pengoptimalan dosis ditunjukan dengan kemampuan menurunkan kekeruhan air dengan efektivitas removal rata-rata di atas 90% yang termasuk pada kategori sangat efektif dan diimbangi dengan optimalnya nilai TDS dan pH air sesuai dengan standar baku mutu yang ditetapkan. | - |
| dc.description.abstract | Water quality testing and the determination of optimal doses of PAC (Poly Aluminium Chloride) and cationic polymers are essential components in the preparation of operational standard procedures (SOPs) in Ciujung river water treatment that have characteristics high of turbidity. The test was conducted using the jar test method referring to SNI 19-6449-2000 with the optimum dosage assessment based on the effectiveness of the isolation of turbidity and stability pH as well as TDS. Based on the results of the tests conducted at the variations of hardness 50-60 NTU, 70-90 NTU, 100-200 NTU and 400-600 NTU the optimal PAC dosage in the range of 90-110 ppm and the dose of 0.3-0,4 ppm for the use of cationic polymers with the optimal slow melting rate at 50 rpm. Dosage optimization is demonstrated by the ability to reduce water stiffness with an average removal effectiveness above 90% which belongs to the category of highly effective and balanced with optimal TDS and water pH values in accordance with the established quality standards | - |
| dc.description.sponsorship | null | - |
| dc.language.iso | id | - |
| dc.publisher | IPB University | id |
| dc.title | Optimisasi Dosis Koagulan dan Flokulan: Pendekatan Penentuan Dosis Optimum dalam Pemulihan Kualitas Air Sungai Ciujung | id |
| dc.title.alternative | Coagulant and Floculant Dosage Optimization: Optimum Dosage Determination Approach in Restoration of Ciujung River Water Quality | - |
| dc.type | Tugas Akhir | - |
| dc.subject.keyword | SOP | id |
| dc.subject.keyword | SOP | id |
| dc.subject.keyword | Poly Aluminum Chloride | id |
| dc.subject.keyword | Polimer | id |
| dc.subject.keyword | Kekeruhan | id |
| dc.subject.keyword | Jar Test | id |
| dc.subject.keyword | Poly Aluminum Chloride | id |
| dc.subject.keyword | Polymers | id |
| dc.subject.keyword | Jar Test | id |
| Appears in Collections: | UT - Environmental Engineering and Management | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| cover_J0313201003_e1c35418051e4d0faa0bf772e1213a90.pdf | Cover | 2.28 MB | Adobe PDF | View/Open |
| fulltext_J0313201003_1f99112ab5204b9f8229ac6f8f7231e4.pdf Restricted Access | Fulltext | 4.76 MB | Adobe PDF | View/Open |
| lampiran_J0313201003_9a30469aa9854ad2ba47a385203f00f6.pdf Restricted Access | Lampiran | 1.57 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.