Title: Tabel Radiografi Standar Regio Thoraks, Abdomen, Ekstremitas dengan X-ray Positioning Bahan Foamed Polysterene
Other Titles: 
Authors: Subangkit, Mawar
Noviana, Deni
Susanto, Ilham Putra
Issue Date: 2024
Publisher: IPB University
Abstract: Tabel radiografi standar adalah tabel yang berisi data atau informasi yang relevan dengan hasil radiografi salah satunya adalah nilai kVp dan mAs. Penelitian ini bertujuan mendapatkan nilai kVP dan mAs standar yang dapat digunakan saat radiografi regio thoraks, abdomen dan ekstremitas menggunakan X-ray positioning bahan foamed polysterene. Nilai kVp dan mAs dihitung terlebih dahulu dengan mengukur ketebalan jaringan hewan untuk mencari nilai perfect exposure sebelum dan sesudah menggunakan X-ray positioning. Nilai perfect exposure didapatkan dengan peningkatan dan penurunan nilai kVp dan mAs standar. Nilai yang menghasilkan pencitraan yang paling baik menjadi perfect exposure. Tabel radiografi standar dibuat dengan menambahkan ketebalan jaringan dan nilai kVp dan mAs. Nilai kVp setiap regio sebelum menggunakan X-ray positioning mempunyai nilai lebih kecil dibandingkan sesudah menggunakan X-ray positioning. Penelitian ini mendapatkan nilai kVp dan mAs standar yang dapat digunakan pada radiografi digital regio thoraks, abdomen dan ekstremitas menggunakan X-ray positioning foamed polysterene dalam bentuk tabel radiografi standar pada X-ray digital.
A Standard radiography tables provide essential data, including kVp (kilovolt- peak) and mAs (milliampere-seconds) values, relevant to radiographic outcomes. This study aims to establish standard kVp and mAs values for digital radiography of the thoracic, abdominal, and extremity regions using foamed polystyrene for X-ray positioning. Initially, kVp and mAs values were calculated by measuring the tissue thickness of animal subjects to determine the perfect exposure both before and after applying the X-ray positioning. The perfect exposure values were identified by systematically adjusting the kVp and mAs until the best imaging quality was achieved. The standard radiography table was constructed by correlating tissue thickness with kVp and mAs values. This research successfully establishes standard kVp and mAs values that can be utilized for digital radiography of the thoracic, abdominal, and extremity regions using foamed polystyrene X-ray positioning. The resulting standard radiography table offers a valuable reference for clinical digital radiography, ensuring optimal image quality through accurate exposure settings
URI: http://repository.ipb.ac.id/handle/123456789/153563
Appears in Collections:UT - Veterinary Clinic Reproduction and Pathology

Files in This Item:
File Description SizeFormat 
cover_B0401201078_2929bb5243f24d7ab21075d36bb7f884.pdfCover614.17 kBAdobe PDFView/Open
fulltext_B0401201078_fb95e333c2e74d92b6640ba0dfda9d67.pdf
  Restricted Access
Fulltext915.82 kBAdobe PDFView/Open
lampiran_B0401201078_d8ca1a28a4e54a21af296e1e43876565.pdf
  Restricted Access
Lampiran170.79 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.