Please use this identifier to cite or link to this item: http://repository.ipb.ac.id/handle/123456789/123483
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorSaptomo, Satyanto Krido-
dc.contributor.advisorKurniawan, Allen-
dc.contributor.authorRosyada, Najwa-
dc.date.accessioned2023-08-10T04:05:19Z-
dc.date.available2023-08-10T04:05:19Z-
dc.date.issued2023-08-10-
dc.identifier.urihttp://repository.ipb.ac.id/handle/123456789/123483-
dc.description.abstractThe textile industry in Pekalongan Regency produces liquid waste from dyeing, starch, printing and finishing activities. The Wastewater Treatment Plant (WWTP) is an effort used by the industry in treating wastewater. WWTP consists of physical processes, combined physico-chemical and biological units. This study aims to evaluate the combination of physicochemical and biological units both in terms of performance and in terms of design based on wastewater characteristics and existing dimensions. Data collection was carried out by observing, interviewing, testing in the field, and testing in the laboratory. Recommendations in the form of adding aerator units and regulating facultative unit influent discharge due to performance and capacity in field conditions that are not met according to analysis. The effect of the biokinetic coefficient on the level of concentration of pollutant load S1 and HRT has been fulfilled even though the coefficient Y and k does not meet the criteria. The influence of SRT biokinetic coefficients is not appropriate due to the absence of Qw. Total TSS production is affected by an increase in the growth rate of biomass (Px). The increase Px is affected by the influent discharge and the increasing coefficient Yobs. Variation of influent discharge also affects the level of food production (F/M) and oxygen demand for microorganisms. Detention times that exceed the criteria for a combination of physicochemical and secondary sedimentation can be corrected by reducing dimensions resulting in minimum volume. The stirrer in the coagulation.id
dc.language.isoidid
dc.publisherIPB Univesityid
dc.titleEvaluasi Kinerja dan Desain Kombinasi Unit Fisika-Kimia (Physicochemical) dan Biologis Air Limbah Tekstilid
dc.title.alternativePerformance Evaluation and Design of Combination of Physicochemical and Biological Textile Wastewater Unitsid
dc.typeUndergraduate Thesisid
dc.subject.keywordtextile wastewaterid
dc.subject.keywordevaluationid
dc.subject.keywordWWTPid
Appears in Collections:UT - Civil and Environmental Engineering

Files in This Item:
File Description SizeFormat 
Cover.pdf
  Restricted Access
Cover1.57 MBAdobe PDFView/Open
Full Text.pdf
  Restricted Access
Full Text2.49 MBAdobe PDFView/Open
Lampiran.pdf
  Restricted Access
Lampiran3.27 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.