Publisher: IPB (Bogor Agricultural University)
Abstract: Suatu struktur bangunan gedung atas beberapa elemen penyusun strukturnya. Indonesia merupakan daerah rawan gempa karena dilalui oleh jalur pertemuan 3 lempeng tektonik. Upaya mitigasi kegagalan struktur di Indonesia akibat gempa sangat perlu dilakukan untuk mengetahui kondisi kinerja struktur bangunan tersebut. Tujuan penelitian ini adalah untuk melakukan pemodelan menggunakan software SAP2000 serta menganalisis kekuatan struktur pada bangunan 8 lantai terhadap gempa. Penelitian dilakukan dengan menggunakan tiga skenario dengan metode respon spektrum. Penyesuaian as built drawing perlu dilakukan karena terdapat perbedaan antara gambar rencana dengan kondisi existing. Pada hasil identifikasi kegagalan struktur Gedung X terdapat kegagalan pada saat beban gempa diinputkan. Terdapat 2 frames yang mengalami overstress pada skenario tiga. Berdasarkan hasil analisis simpangan antar lantai dan efek P-Δ, Gedung X dinilai aman karena nilai yang didapat tidak melebihi simpangan izin. Rekomendasi struktur berupa penambahan dimensi kolom menjadi 500 mm × 500 mm, serta pembesaran diameter tulangan menjadi 32 mm.
A building structure consists of several structural elements. Indonesia is an earthquake-prone area because it is traversed by the meeting point of 3 tectonic plates. Mitigation of structural failures in Indonesia due to earthquakes really needs to be done to determine the performance conditions of these building structures. The purpose of this research is to perform modeling using SAP2000 software and to analyze the structural strength of an 8-storey building against earthquakes. The research was conducted using three scenarios with the response spectrum method. Adjustments to the as built drawings need to be made because there are differences between the plans and the existing conditions. In the identification results of the failure of the X Building structure there is a failure when the earthquake load is input. There are 2 frames that experience overstress in scenario three. Based on the analysis of the deviation between floors and the P-Δ effect, Building X is considered safe because the value obtained does not exceed the permit deviation. Structural recommendations include adding column dimensions to 500 mm × 500 mm, and increasing the reinforcement diameter to 32 mm.
URI: http://repository.ipb.ac.id/handle/123456789/123151
Appears in Collections:UT - Civil and Environmental Engineering

Files in This Item:
File Description SizeFormat 
Cover, Lembar Pengesahan, Prakata, Daftar Isi.pdf
  Restricted Access
Cover727.75 kBAdobe PDFView/Open
F44190055_Raihan Daffa Hukama.pdf
  Restricted Access
Fulltext5.26 MBAdobe PDFView/Open
Lampiran.pdf
  Restricted Access
Lampiran3.46 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.