Please use this identifier to cite or link to this item:
http://repository.ipb.ac.id/handle/123456789/112308
Title: | Uji Coba Aplikasi Sistem Pemipaan untuk Pencegahan Serangan Rayap Tanah pada Bangunan Gedung – Pra Konstruksi |
Other Titles: | Field Trial of the Reticulation System for Prevention of Subterranean Termite Attacks on Buildings |
Authors: | Nandika, Dodi Arinana, Arinana Rahayu, Agustina Muji |
Issue Date: | 2022 |
Publisher: | IPB University |
Abstract: | Pengendalian serangan rayap pada bangunan gedung yang paling banyak diterapkan adalah perlakuan tanah. Pada perlakuan tanah konvensional, perlakuan ulang hanya dapat dilakukan dengan pengeboran pada lantai bangunan, disusul oleh penginjeksian larutan ke dalam liang pengeboran. Metode ini kurang menjamin kemerataan larutan termitisida di bawah lantai bangunan. Oleh karena itu berkembanglah metode pencegahan serangan rayap tanah dengan sistem pemipaan (termite reticulation system) yang memungkinkan aplikasi termitisida secara berkala tanpa harus merusak lantai bangunan. Penelitian ini bertujuan mengetahui waktu standar, unsur kerja paling kritis dari sistem pemipaan, elongasi Pipa Tetes, kemerataan larutan, kadar residu dan viskositas larutan termitisida. Hasil penelitian menunjukkan aplikasi sistem pemipaan memerlukan waktu standar 125,94 menit dengan unsur kerja penyaluran larutan termitisida sebagai titik kritisnya. Penyaluran larutan termitisida cukup merata dengan volume rata-rata 55±5,18 mL/menit; residu bahan aktif termitisida mencapai 40,98 ppm; nilai viskositas larutan sebesar 1,92 cP; dan nilai elongasi Pipa Tetes mencapai 507,45%. The control of termite attacks in buildings that is most applied is soil treatment. In the application of conventional, re-treatment can only be done by drilling the floor, followed by injecting the solution into the holes. This method does not guarantee an even distribution of the solution. Therefore, a method of preventing subterranean termite attack has been developed with a termite reticulation system that allows the application of termiticides on a regular basis without damage the floor. This study aims to determine the standard time, critical point of piping system, elongation the drip pipe, the evenness, residual content and viscosity of the termiticide solution. The results showed that the application of the drip piping required a standard time of 125,94 minutes with the working element of the termiticide solution distribution as the critical point. The distribution of the termiticide solution is quite evenly distributed with an average volume of 55±5,18 mL/minute; the thermic active residue in the soil reached 40,98 ppm; viscosity of the solution was 1,92 cP; and the elongation of the drip pipe reached 507,45%. |
URI: | http://repository.ipb.ac.id/handle/123456789/112308 |
Appears in Collections: | UT - Forestry Products |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
E24180005_Cover.pdf Restricted Access | Cover | 490.03 kB | Adobe PDF | View/Open |
E24180005_Agustina Muji Rahayu.pdf Restricted Access | Fullteks | 1.97 MB | Adobe PDF | View/Open |
E24180005_Lampiran.pdf Restricted Access | Lampiran | 2.48 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.