Please use this identifier to cite or link to this item:
http://repository.ipb.ac.id/handle/123456789/112128| Title: | Formulasi Indeks Kenyamanan Ruang Gedung Olahraga di Kabupaten Kebumen |
| Other Titles: | Formulation of Indoor Air Comfort Index for in The District Kebumen Gymnasium |
| Authors: | Yuwono, Arief Sabdo Styawan, Welly Ageng |
| Issue Date: | 2022 |
| Publisher: | IPB University |
| Abstract: | Kenyamanan pengguna gedung olahraga menjadi faktor yang perlu
diperhatikan dalam pembangunan gedung olahraga. Penelitian ini bertujuan
menyusun formulasi indeks kenyamanan ruang pada gedung olahraga dengan
memperhitungkan kondisi intensitas cahaya, kebisingan, suhu udara ruang,
kebauan, dan kelembaban relatif. Metode kuantitatif dan metode kualitatif
digunakan pada penelitian ini. Metode kuantitatif didasarkan pada pengukuran lima
parameter di gedung olahraga dan metode kualitatif didasarkan pada pengisian
kuesioner oleh responden. Formula indeks kenyamanan udara dalam ruang (KUR)
diperoleh dari total perkalian antara nilai bobot masing-masing parameter dengan
indeksnya. Berdasarkan hasil pengisian kuesioner yang diisi oleh 75 responden
diperoleh nilai bobot untuk intensitas cahaya sebesar 0,27, suhu sebesar 0,22,
kelembaban relatif sebesar 0,18, kebisingan sebesar 0,17, dan kebauan sebesar 0,16.
Pengukuran pada delapan gedung olahraga mendapatkan nilai rata-rata suhu
sebesar 28,4 ℃, kebisingan sebesar 65,7 dB(A), kebauan sebesar -0,1, kelembaban
relatif sebesar 89,1 %, dan intensitas cahaya sebesar 36,6 lux. Berdasarkan hasil
penelitian, kedelapan gedung olahraga di Kabupaten Kebumen berpredikat cukup
nyaman dengan nilai indeks KUR 2,1-2,5. In constructing a gymnasium, the comfort of gymnasium users should be a considered factor. This study aims to obtain a spatial comfort index formulation in a gymnasium by considering the conditions of light intensity, noise, temperature, odor, and relative humidity. Quantitative methods and qualitative methods are used in this study. Five parameters measured in the gymnasium are used in the quantitative method. Meanwhile, questionnaires filled by respondents are used in the qualitative method. The equation for indoor air comfort index (KUR) is obtained from the total multiplication between the weight values of each parameter and its index. Based on the filled out questionnaires conducted by 75 respondents, the weight value for light intensity is 0,27, the temperature is 0,22, relative humidity is 0,18, noise is 0,17, and odour is 0,16. Measurements at eight gymnasia obtained an average temperature value of 28,4 ℃, noise of 65,7 dB(A), the odour of -0,1, relative humidity of 89,1 %, and light intensity of 36,6 lux. This study showed that the eight gymnasia in Kebumen Regency were considered quite comfortable with a KUR index value of 2,1-2,5. |
| URI: | http://repository.ipb.ac.id/handle/123456789/112128 |
| Appears in Collections: | UT - Civil and Environmental Engineering |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| Cover, Lembar Pernyataan, Abstrak, Lembar Pengesahan, Prakata dan Daftar Isi.pdf Restricted Access | Cover | 2.44 MB | Adobe PDF | View/Open |
| F44180033_Welly Ageng Styawan.pdf Restricted Access | Fullteks | 3.6 MB | Adobe PDF | View/Open |
| Lampiran.pdf Restricted Access | Lampiran | 2.87 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.