View Item 
      •   IPB Repository
      • Dissertations and Theses
      • Undergraduate Theses
      • UT - Faculty of Mathematics and Natural Sciences
      • UT - Physics
      • View Item
      •   IPB Repository
      • Dissertations and Theses
      • Undergraduate Theses
      • UT - Faculty of Mathematics and Natural Sciences
      • UT - Physics
      • View Item
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      Simulasi Teknik 3D-CRT menggunakan Metode Monte Carlo EGSnrc pada Fantom CT

      Thumbnail
      View/Open
      Cover (853.2Kb)
      Fullteks (1.667Mb)
      Lampiran (687.1Kb)
      Date
      2022
      Author
      Noviantoro, Yosia Adityo
      Husin, Abd. Djamil
      Yani, Sitti
      Metadata
      Show full item record
      Abstract
      3D-CRT merupakan salah satu teknik radioterapi yang digunakan untuk meminimalisir efek samping dari radioterapi dengan cara melakukan penyinaran radiasi dari berbagai sudut. Simulasi teknik penyinaran 3D-CRT dilakukan untuk menentukan distribusi dosis yang akan diterima oleh target sebelum diaplikasikan kepada pasien. Simulasi yang dilakukan menggunakan program EGSnrc berbasis monte carlo pada fantom homogen virtual dengan material PMMA yang bersumber dari data CT fantom ArcCheck. Berbagai sudut yang digunakan yaitu sudut 0°, 45°, 90°, 135°, 180° dan 270° untuk mensimulasikan teknik penyinaran 3D-CRT. Hasil simulasi menunjukkan karakteristik distribusi dosis pada fantom bernilai maksimum di daerah sekitar permukaan. Penjumlahan distribusi dosis pada semua sudut menghasilkan dosis maksimum pada daerah isocenter. Hal ini sudah sesuai dengan tujuan dari teknik 3D-CRT. Perbandingan distribusi dosis antara hasil simulasi dan hasil eksperimen menunjukkan bahwa distribusi dosis keduanya sama secara kualitatif.
       
      3D-CRT is one of the radiotherapy techniques used to minimize the side effects of radiotherapy by delivering radiation from various angles. Simulation of the 3D-CRT technique was performed to determine the distribution dose received by the target before it was applied to the patient. Simulations were carried out using the Monte Carlo-based EGSnrc program on a virtual homogeneous phantom with PMMA material from ArcCheck phantom CT data. Simulation of the 3D-CRT technique using various angles, such as 0°, 45°, 90°, 135°, 180°, and 270°. The simulation results show the proper distribution of the dose on the phantom in the area around the surface. The accumulation of distribution dose from all angles produces a maximum dose at the isocenter. This corresponds to the 3D-CRT technique. The comparison of simulation and experimental results shows that the distribution doses are qualitatively the same.
       
      URI
      http://repository.ipb.ac.id/handle/123456789/114157
      Collections
      • UT - Physics [1236]

      Copyright © 2020 Library of IPB University
      All rights reserved
      Contact Us | Send Feedback
      Indonesia DSpace Group 
      IPB University Scientific Repository
      UIN Syarif Hidayatullah Institutional Repository
      Universitas Jember Digital Repository
        

       

      Browse

      All of IPB RepositoryCollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

      My Account

      Login

      Application

      google store

      Copyright © 2020 Library of IPB University
      All rights reserved
      Contact Us | Send Feedback
      Indonesia DSpace Group 
      IPB University Scientific Repository
      UIN Syarif Hidayatullah Institutional Repository
      Universitas Jember Digital Repository