View Item 
      •   IPB Repository
      • IPBana
      • Published by Others
      • Faculty of Mathematics and Natural Sciences
      • View Item
      •   IPB Repository
      • IPBana
      • Published by Others
      • Faculty of Mathematics and Natural Sciences
      • View Item
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      INHIBITION KINETICS OF Sida rhombifolia L. EXTRACT TOWARD XANTHINE OXIDASE BY ELECTROCHEMICAL METHOD

      Thumbnail
      View/Open
      Fulltext (220.7Kb)
      Date
      2014
      Author
      Iswantini, Dyah
      Yulian, Muammar
      Mulijani, Sri
      Trivadila
      Metadata
      Show full item record
      Abstract
      Sida rhombifolia L. is a traditional medicinal plant that has been known with potential as antigout. The previous research suggested that flavonoids crude extract of S. rhombifolia had an inhibitory activity toward xanthine oxidase by 71% and a spectrophotometric measurement showed that the type of flavonoids crude extract inhibition was a competitive inhibition. The purpose of the research was to investigate the type of inhibition kinetic of S. Rhombifolia’s ethanol extract by electrochemical method and to compare the measurements of linearity and sensitivity between spectrophotometric and electrochemical methods. The results showed that the yield of S. Rhombifolia’s ethanol extract was 9.82% with the inhibitory activity ranging from 13.64% to 82.69% (5.00-200 mg L-1) and IC50 value was 91.15±5.74 mg L-1. Allopurinol as a control showed the inhibitory activity of 15.26-70.95% (0.10-4.00 mg L-1) and IC50 value was 2.45±2.21 mg L-1. Inhibition kinetics of the ethanol extract caused a KM increase and unchange of VMAX. Based on the data, the type of inhibition kinetics was a competitive inhibition, with an inhibitor affinity (α) value of 3.18. Linearity of xanthine oxidase activity assay by electrochemical and spectrophotometric methods showed the range of 0.01-1.00 mM (R2 = 0.978) and 0.05-0.70 mM (R2 = 0.977) respectively. The sensitivity of electrochemical method was reported higher (0.95 μA mM-1) than the spectrophotometric method (0.007 min-1).
      URI
      http://repository.ipb.ac.id/handle/123456789/76469
      Collections
      • Faculty of Mathematics and Natural Sciences [471]

      Copyright © 2020 Library of IPB University
      All rights reserved
      Contact Us | Send Feedback
      Indonesia DSpace Group 
      IPB University Scientific Repository
      UIN Syarif Hidayatullah Institutional Repository
      Universitas Jember Digital Repository
        

       

      Browse

      All of IPB RepositoryCollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

      My Account

      Login

      Application

      google store

      Copyright © 2020 Library of IPB University
      All rights reserved
      Contact Us | Send Feedback
      Indonesia DSpace Group 
      IPB University Scientific Repository
      UIN Syarif Hidayatullah Institutional Repository
      Universitas Jember Digital Repository