Abstract
On this research would do waste water filtration by using membrane of teflon and cellulose acetate. The method was used is a dead end for teflon and for cellulose acetate membrane method will use dead-end and cross-flow. It also would have done three variations of pressure for each treatment. From the results of research on deadend with PTFE membrane needs to be greater pressure than cellulose acetate. For a dead-end debit highest on PTFE pressure 5.8 psi with a value of 0,604 ml/minute and flux of 0.625 cm/min. For a dead-end with cellulose acetate membrane meliki highest debit on the pressure of 7.5 psi with the value 0.41 ml/minute and fluksnya 0.06 cm/min. whereas cross-flow membrane cellulose acetate produces the highest debit 0.42 ml/min and the highest flux 0.021 cm/min at a pressure of 7.5 psi. for the lowest value of turbidity characteristics possessed by the process of cross-flow at pressure 5 psi with a value of 0.22 NTU. Most neutral acidity was owned by the process deadend with cellulose acetate membrane pressure 2.5 psi. type the lowest value for the masses was a product of cross-flow with a pressure of 5 psi with a value of 1,02606 gr/cm3. Total solids remaining the lowest also owned by the product of cross-flow filtration pressure 5 psi. for the lowest value of viscosity obtained on the process dead-end with teflon membrane on the pressure of 5.8 psi.