dc.contributor.advisor | Puspita, R. Tony Ibnu Sumaryada Wijaya | |
dc.contributor.advisor | Yani, Sitti | |
dc.contributor.author | Uzlifah, Maulida Janatu | |
dc.date.accessioned | 2024-08-28T06:21:57Z | |
dc.date.available | 2024-08-28T06:21:57Z | |
dc.date.issued | 2024 | |
dc.identifier.uri | http://repository.ipb.ac.id/handle/123456789/158506 | |
dc.description.abstract | Penelitian ini menggunakan simulasi Monte Carlo untuk membandingkan
kurva isodosis dan dose volume histogram pada fantom inhomogen yang diradiasi
dengan Cobalt-60. Sumber radioaktif ditempelkan dalam polyethylene. Ukuran
fantom, yaitu 10 × 10 × 10 cm3
. Penelitian ini menggunakan target berukuran 2 cm
× 2 cm × 3 mm dan 2 cm × 2 cm × 5 mm. Jarak target simulasi dengan sumber
radioaktif, yaitu 0 dan 3 mm. Hasil penelitian menunjukkan penurunan dosis pada
target seiring bertambahnya kedalaman (5 mm, 7 mm, 10 mm) karena atenuasi
radiasi. Faktor lain yang memengaruhi adalah densitas target, dimana target dengan
densitas lebih tinggi menyerap lebih banyak radiasi. Brakiterapi terbukti efektif
untuk target dangkal (5-7 mm) dengan distribusi dosis mencapai 20%-40% dari
dosis maksimum. Namun, efektivitasnya menurun pada target yang lebih dalam
(>10 mm) karena dosis yang diterima target berkurang hingga di bawah 10% dari
dosis maksimum. | |
dc.description.abstract | This study used Monte Carlo simulation to compare isodose curves and
dose volume histograms on inhomogeneous phantoms irradiated with Cobalt-60.
The radioactive source was attached to polyethylene. The size of the phantom was
10 × 10 × 10 cm3
. This study used 2 cm × 2 cm × 3 mm and 2 cm × 2 cm × 5 mm
targets. The distance between the simulated target and the radioactive source was 0
and 3 mm. The results show a decrease in the dose to the target as the depth
increases (5 mm, 7 mm, 10 mm) due to radiation attenuation. Another influencing
factor is the target density, where higher-density targets absorb more radiation.
Brachytherapy is effective for shallow targets (5-7 mm) with dose distribution
reaching 20%-40% of the maximum dose. However, its effectiveness decreases
in deeper targets (>10 mm) | |
dc.description.sponsorship | | |
dc.language.iso | id | |
dc.publisher | IPB University | id |
dc.title | Simulasi Monte Carlo Brakiterapi pada Kanker
Superfisial dengan Sumber Co-60 | id |
dc.title.alternative | Monte Carlo Simulation Superficial Cancer
Brachytherapy using Source Co-60 | |
dc.type | Skripsi | |
dc.subject.keyword | Brachytherapy | id |
dc.subject.keyword | Cobalt-60 | id |
dc.subject.keyword | Dose Volume Histogram | id |
dc.subject.keyword | Isodose Curves | id |
dc.subject.keyword | Superficial Cancer | id |