dc.description.abstractDalam bidang radiodiagnostik, diperlukan hasil pencitraan yang baik untuk ketepatan dalam mendiagnosis suatu penyakit. Alat bantu positioning dapat mempertahankan posisi hewan, untuk menciptakan hasil pencitraan yang optimal. Penelitian ini bertujuan untuk menggunakan bahan lokal foamed polystyrene sebagai bahan dasar pembuatan alat bantu positioning radiografi pada regio toraks. Busa polystyrene dibentuk sesuai desain yang sudah dibuat dan dilapisi dengan kain sintetik. Prototipe yang sudah jadi kemudian diuji menggunakan digital radiografi dengan hewan coba kucing jantan. Pencitraan dilakukan pada regio toraks kucing dari berbagai sudut pandang dengan dan tanpa menggunakan alat bantu. Hasil dibandingkan dan dianalisis dengan bantuan komputer. Berdasarkan hasil evaluasi gambar radiografi yang diambil, pencitraan menggunakan prototipe memiliki hasil yang lebih baik pada regio toraks. Hal ini terlihat dari fokus organ dan jaringan yang terlihat lebih jelas pada saat menggunakan alat bantu prototipe. Berdasarkan hasil di atas, bahan lokal foamed polystyrene terbukti dapat dijadikan sebagai bahan dasar untuk prototipe positioning radiografi pada regio toraks.
dc.description.abstractIn the field of radiodiagnostics, good imaging results are needed for accuracy in diagnosing a disease. Positioning aids can maintain the animal's position, to create optimal imaging results. This research aims to use local foamed polystyrene as a basic material for making radiographic positioning aids in the thoracic region. Polystyrene foam is formed according to a pre-made design and covered with synthetic fabric. The finished prototype was then tested using digital radiography with male cat animals. Imaging was performed on the cat's thoracic region from various angles with and without the use of assistive devices. Results are compared and analyzed with the help of a computer. Based on the evaluation results of the radiographic images taken, imaging using the prototype had better results in the thoracic region. This can be seen from the focus of organs and tissues which are seen more clearly when using the prototype tool. Based on the results above, local foamed polystyrene material has been proven to be used as a basic material for radiographic positioning prototypes in the thoracic region.
dc.description.sponsorship
dc.language.isoid
dc.publisherIPB Universityid
dc.titleFoamed Polystyrene sebagai Bahan X-ray Positioning Radiografi Regio Toraksid
dc.title.alternativeFoamed Polystyrene as a Material for X-ray Positioning Radiography of the Thoracic Region
dc.typeSkripsi
dc.subject.keywordfoamed polystyreneid
dc.subject.keywordpositioningid
dc.subject.keywordradiography positioningid
dc.subject.keywordaidsid
dc.subject.keywordthoraxid