Show simple item record

dc.contributor.advisorPuspita, Tony Ibnu Sumaryada Wijaya
dc.contributor.advisorYani, Sitti
dc.contributor.authorAuliazahra, Vanni
dc.date.accessioned2023-09-22T08:16:37Z
dc.date.available2023-09-22T08:16:37Z
dc.date.issued2023
dc.identifier.urihttp://repository.ipb.ac.id/handle/123456789/125287
dc.description.abstractTujuan penelitian ini adalah untuk memperoleh informasi terkait pengaruh penambahan partikel emas pada kanker payudara menggunakan simulasi Monte Carlo. Objek penelitian menggunakan fantom kanker payudara yang tersusun dari beberapa material yaitu adiposa, air, tulang, paru-paru, dan emas. Energi radiasi yang digunakan adalah foton 6 dan 10 MeV, dan elektron 6 dan 9 MeV. Hasil yang diperoleh berupa kurva PDD, kurva profil, dan Dose Enhancement Ratio (DER). Kurva PDD diperoleh hasil bahwa dosis maksimum 100% pada fantom yang diradiasi foton 6 dan 10 MeV, dan elektron 6 dan 9 MeV masing – masing berada di kedalaman 2,10 cm dan 1,90 cm. Pada kurva profil menunjukkan korelasi antara besarnya kedalaman dengan nilai Full Width Half Maximum (FWHM) yang semakin lebar dengan penurunan dosis radiasi. Nilai DER maksimum pada foton dan elektron masing-masing berada di kedalaman 2,10 cm dan 1,90 cm dengan besar 2,02% pada foton 6 MeV, 3,45% pada foton 10 MeV, 1,49% pada elektron 6 MeV, dan 1,46% pada elektron 9 MeV.id
dc.description.abstractThis study aimed to obtain information regarding the effect of adding gold particles on breast cancer using a Monte Carlo simulation. The research object used a breast cancer phantom composed of several materials: adipose, water, bone, lungs, and gold. The radiation energy used is 6 and 10 MeV photons, 6 and 9 MeV electrons. The results obtained are PDD curves, profile curves, and Dose Enhancement Ratio (DER). The PDD curve shows that the maximum dose of 100% in the phantom irradiated with 6 and 10 MeV photons and 6 and 9 MeV electrons is at a depth of 2,10 cm and 1,90 cm, respectively. The profile curve shows the correlation between the depth and the Full Width Half Maximum (FWHM) value which gets wider with a decrease in radiation dose. The maximum DER values for photons and electrons are at a depth of 2,10 cm and 1,90 cm, respectively, with a magnitude of 2,02% for 6 MeV photons, 3,45% for 10 MeV photons, 1,49% for 6 MeV electrons, and 1,46% for 9 MeV electrons.id
dc.language.isoidid
dc.publisherIPB Universityid
dc.titlePerbandingan Distribusi Dosis Pada Fantom Kanker Payudara Dengan Penambahan Partikel Emas Yang Diradiasi Foton dan Elektronid
dc.title.alternativeComparison of Dose Distribution in Phantom Breast Cancer With the Addition of Gold Particles Radiated by Photons and Electronsid
dc.typeUndergraduate Thesisid
dc.subject.keywordgoldid
dc.subject.keywordmonte carloid
dc.subject.keywordradiosensitizerid


Files in this item

Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record